Brain temperature measurements in rats: a comparison of microwave and ambient temperature exposures.

PAPER pubmed Bioelectromagnetics 1986 Animal study Effect: no_effect Evidence: Low

Abstract

In an effort to understand microwave heating better, regional brain and core temperatures of rats exposed to microwave radiation (2450 MHz) or elevated air temperatures were measured in two studies. In general, we have found no substantial evidence for temperature differentials, or "hot spots," in the brain of these animals. In the first study, after a 30-min exposure, no temperature differences between brain regions either after microwave or ambient air exposure were found. However, a highly significant correlation between brain and core temperatures was found and this correlation was the same for both microwave and ambient air heating. In the second study, time-temperature profiles were measured in rats exposed to either 30 mW/cm2 or 36.2 degrees C. In this study, the 30-min exposure period was divided into seven intervals and the change in temperature during each period was analyzed. Only the cortex showed significantly different heating rates between the air heating and microwave heating; however, this difference disappeared after the initial 5 min of exposure.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Rats
Sample size
Exposure
microwave · 2450 MHz · 30 min
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Across two studies in rats, the authors report no substantial evidence for regional brain temperature differentials (“hot spots”) after 30-min exposures to 2450 MHz microwaves or elevated ambient air temperature. In one study, no temperature differences between brain regions were found after either exposure, and brain temperature correlated strongly with core temperature similarly for both heating methods. In a second study, only cortex showed different heating rates between air heating and microwave heating, but this difference was limited to the initial 5 minutes and was not present thereafter.

Outcomes measured

  • Regional brain temperature
  • Core temperature
  • Brain temperature differentials (“hot spots”)
  • Heating rates/time-temperature profiles

Limitations

  • Sample size not reported in abstract
  • Exposure metric reported as power density (mW/cm2) rather than SAR; dosimetry details not provided in abstract
  • Animal study; generalizability to humans not addressed in abstract
  • Limited outcome scope (temperature measures only)
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "microwave",
        "source": null,
        "frequency_mhz": 2450,
        "sar_wkg": null,
        "duration": "30 min"
    },
    "population": "Rats",
    "sample_size": null,
    "outcomes": [
        "Regional brain temperature",
        "Core temperature",
        "Brain temperature differentials (“hot spots”)",
        "Heating rates/time-temperature profiles"
    ],
    "main_findings": "Across two studies in rats, the authors report no substantial evidence for regional brain temperature differentials (“hot spots”) after 30-min exposures to 2450 MHz microwaves or elevated ambient air temperature. In one study, no temperature differences between brain regions were found after either exposure, and brain temperature correlated strongly with core temperature similarly for both heating methods. In a second study, only cortex showed different heating rates between air heating and microwave heating, but this difference was limited to the initial 5 minutes and was not present thereafter.",
    "effect_direction": "no_effect",
    "limitations": [
        "Sample size not reported in abstract",
        "Exposure metric reported as power density (mW/cm2) rather than SAR; dosimetry details not provided in abstract",
        "Animal study; generalizability to humans not addressed in abstract",
        "Limited outcome scope (temperature measures only)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "rats",
        "brain temperature",
        "core temperature",
        "microwave heating",
        "2450 MHz",
        "ambient air heating",
        "hot spots",
        "power density",
        "cortex"
    ],