Health implications of exposure to radiofrequency/microwave energies.
Abstract
ABSTRACT The rapid development of and the increase in the number and variety of devices that emit microwave/radiofrequency (MW/RF) energies has resulted in a growing interest regarding the potential effects on health of these energies. The frequency ranges considered in this review are: 300 kHz to 300 MHz (radiofrequency) and 300 MHz to 300 GHz (microwaves). Investigations have shown that exposure to certain power densities for several minutes or hours can result in pathophysiological manifestations in laboratory animals. Such effects may or may not be characterised by a measurable rise in temperature, which is a function of thermal regulatory processes and active adaptation by the animal. The end result is either a reversible or irreversible change, depending on the irradiation conditions and the physiological state of the animal. At lower power densities, evidence of pathological changes or physiological alteration is non-existent or equivocal. Much discussion, nevertheless, has taken place on the relative importance of thermal or non-thermal effects of radiofrequency and microwave radiation. Several retrospective studies have been done on human populations exposed or believed to have been exposed to MW/RF energies. Those performed in the US have not shown any relationship of altered morbidity or mortality to MW/RF exposure. Reactions referrable to the central nervous system and cardiovascular effects from exposure of man to microwave energy have been reported mostly in Eastern European publications. Individuals suffering from various ailments or psychological factors may exhibit the same dysfunctions of the central nervous and cardiovascular systems as those reported to result from exposure to MW/RF; thus it is extremely difficult, if not impossible, to rule out other factors in attempting to relate MW/RF exposure to clinical conditions. There is a need to set limits on the amount of exposure to MW/RF energies that individuals can accept with safety. Operative protection standards have apparently provided adequate safety to workers and the general population to permit the use of MW/RF energies without harm or detriment.
AI evidence extraction
Main findings
The review covers RF (300 kHz–300 MHz) and microwave (300 MHz–300 GHz) exposures. Animal investigations are described as showing pathophysiological manifestations at certain power densities over minutes to hours, with effects variably associated with measurable temperature rise and potentially reversible or irreversible depending on conditions. At lower power densities, evidence for pathological or physiological alteration is described as non-existent or equivocal; US retrospective human studies are described as not showing altered morbidity or mortality related to MW/RF exposure, while CNS and cardiovascular reactions are reported mostly in Eastern European publications with substantial difficulty excluding other factors.
Outcomes measured
- pathophysiological manifestations (animals)
- temperature rise/thermal regulation
- reversible or irreversible change (animals)
- pathological changes or physiological alteration at lower power densities
- morbidity
- mortality
- central nervous system reactions
- cardiovascular effects
Limitations
- Review article; no primary study methods or pooled estimates provided in abstract
- Human evidence described as retrospective and includes populations 'exposed or believed to have been exposed' (potential exposure misclassification)
- Abstract notes difficulty ruling out other factors (confounding) when relating clinical conditions to MW/RF exposure
- Power density thresholds and quantitative exposure metrics not specified in abstract
Suggested hubs
-
occupational-exposure
(0.62) Discusses retrospective studies of exposed human populations and mentions worker safety standards.
View raw extracted JSON
{
"study_type": "review",
"exposure": {
"band": "RF/microwave",
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": "several minutes or hours (animal exposure mentioned)"
},
"population": "Laboratory animals; human populations exposed or believed to have been exposed to MW/RF energies (retrospective studies)",
"sample_size": null,
"outcomes": [
"pathophysiological manifestations (animals)",
"temperature rise/thermal regulation",
"reversible or irreversible change (animals)",
"pathological changes or physiological alteration at lower power densities",
"morbidity",
"mortality",
"central nervous system reactions",
"cardiovascular effects"
],
"main_findings": "The review covers RF (300 kHz–300 MHz) and microwave (300 MHz–300 GHz) exposures. Animal investigations are described as showing pathophysiological manifestations at certain power densities over minutes to hours, with effects variably associated with measurable temperature rise and potentially reversible or irreversible depending on conditions. At lower power densities, evidence for pathological or physiological alteration is described as non-existent or equivocal; US retrospective human studies are described as not showing altered morbidity or mortality related to MW/RF exposure, while CNS and cardiovascular reactions are reported mostly in Eastern European publications with substantial difficulty excluding other factors.",
"effect_direction": "mixed",
"limitations": [
"Review article; no primary study methods or pooled estimates provided in abstract",
"Human evidence described as retrospective and includes populations 'exposed or believed to have been exposed' (potential exposure misclassification)",
"Abstract notes difficulty ruling out other factors (confounding) when relating clinical conditions to MW/RF exposure",
"Power density thresholds and quantitative exposure metrics not specified in abstract"
],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"microwave",
"MW/RF",
"power density",
"thermal effects",
"non-thermal effects",
"occupational exposure",
"morbidity",
"mortality",
"central nervous system",
"cardiovascular"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.61999999999999999555910790149937383830547332763671875,
"reason": "Discusses retrospective studies of exposed human populations and mentions worker safety standards."
}
]
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.