Share
𝕏 Facebook LinkedIn

Prolonged microwave irradiation of rats: effects on concurrent operant behavior.

PAPER pubmed Bioelectromagnetics 1981 Randomized trial Effect: mixed Evidence: Moderate

Abstract

Two measures of performance were used to study the effects of pulse-modulated microwave radiation (PM MWR) on schedule-controlled operant behavior of rats: 1) cued (SD), fixed-ratio (FR) bar pressing for food reinforcement; and 2) noncued (Sd) bar pressing in the absence of food reinforcement. The animals were irradiated and the behavioral data were obtained concurrently, during daily three-hour sessions, five days per week for six to nine weeks. Each experiment began with a two to three-week baseline interval of sham irradiation; a two to three-week interval of sham irradiation followed the irradiation phase. The irradiated animals were exposed to 1.3-Ghz PM MWR (pulse width of 1 microsecond at 600 pulses per second) at whole-body, average specific absorbed-dose rates of from 1.5-6.7 m W/g. Control and irradiated animals were tested in identical, cylindrical waveguide exposure/behavioral assemblies; different groups of irradiated and sham-irradiated animals were used for each dose rate. At 1.5 mW/g, the levels of SD operant responding by control and irradiated animals were comparable, and showed similar progressive diminutions over the course of each daily session. Sd operant responding was more variable, but again comparable, with both groups showing similar, progressive declines in rate of responding during each session. At 3.6 mW/g, no specific effects on SD operant response rates were observed. However, there was an initial and transient increase in the rate of extinction of Sd responding. At 6.7 mW/g, SD response rates were slightly reduced, whereas there was a major reduction in noncued (Sd) operant responding followed by a sharp rebound during the first post-MWR week. This marked reduction in Sd operant responding at MWR onset was in contrast to the relative stability and persistence of FR responding for food reinforcement.

AI evidence extraction

At a glance
Study type
Randomized trial
Effect direction
mixed
Population
rats
Sample size
Exposure
microwave · 1300 MHz · daily three-hour sessions, five days per week for six to nine weeks
Evidence strength
Moderate
Confidence: 60% · Peer-reviewed: yes

Main findings

At 1.5 mW/kg, no differences in operant responding between control and irradiated rats were observed. At 3.6 mW/kg, no effect on cued responding but a transient increase in extinction rate of noncued responding occurred. At 6.7 mW/kg, slight reduction in cued responding and major reduction in noncued responding followed by rebound post-exposure were observed.

Outcomes measured

  • cued (SD) fixed-ratio bar pressing for food reinforcement
  • noncued (Sd) bar pressing without food reinforcement

Limitations

  • sample size not specified
  • only rat model studied
  • only specific behavioral measures assessed
View raw extracted JSON
{
    "study_type": "randomized_trial",
    "exposure": {
        "band": "microwave",
        "source": null,
        "frequency_mhz": 1300,
        "sar_wkg": null,
        "duration": "daily three-hour sessions, five days per week for six to nine weeks"
    },
    "population": "rats",
    "sample_size": null,
    "outcomes": [
        "cued (SD) fixed-ratio bar pressing for food reinforcement",
        "noncued (Sd) bar pressing without food reinforcement"
    ],
    "main_findings": "At 1.5 mW/kg, no differences in operant responding between control and irradiated rats were observed. At 3.6 mW/kg, no effect on cued responding but a transient increase in extinction rate of noncued responding occurred. At 6.7 mW/kg, slight reduction in cued responding and major reduction in noncued responding followed by rebound post-exposure were observed.",
    "effect_direction": "mixed",
    "limitations": [
        "sample size not specified",
        "only rat model studied",
        "only specific behavioral measures assessed"
    ],
    "evidence_strength": "moderate",
    "confidence": 0.59999999999999997779553950749686919152736663818359375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "microwave radiation",
        "pulse-modulated microwave",
        "operant behavior",
        "rats",
        "behavioral effects",
        "specific absorbed dose"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.