Latest

1566 posts

Response identification in the extremely low frequency region of an electret condenser microphone.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured…

Mobile phones and short message service texts to collect situational awareness data during simulated public health critical events.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This university-based pilot study evaluated whether two-way SMS text messaging could be used to collect situational assessment data during simulated public health critical events. Among 63 enrolled students, 76.7% of prompted SMS surveys were completed, and most responses were returned quickly.…

Effect of magnetic fields on tumor growth and viability.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This animal study evaluated whether magnetic field exposure affects breast tumor growth and viability in mice injected with breast cancer cells. Tumor growth was monitored in real time using luciferase labeling and an in vivo imaging system. The authors report that 360 minutes of daily magnetic…

[Clinical efficacy of acne scar treatment with micro-plasma radio frequency].

RF Safe Research Library Jan 1, 2011 NEUTRAL LOW

This clinical study evaluated micro-plasma radio frequency treatment for facial acne scars in 24 patients. Patients received 3–5 treatments and were assessed using photographs before and 2 months after treatment. The authors report an overall improvement rate of 83.33% and conclude the technique…

Design and implementation of a wireless sensor network-based remote water-level monitoring system.

RF Safe Research Library Jan 1, 2011 NEUTRAL UNKNOWN

This article reports an engineering implementation of a wireless sensor network-based remote water-level monitoring system. The system includes field sensors, a base station, a data center, and a web publishing module, and is described as providing real-time monitoring and anti-jamming capability.…

Effects of extremely low frequency magnetic field on oxidative balance in brain of rats.

RF Safe Research Library Jan 1, 2011 CONCERN MEDIUM

This animal study examined whether an extremely low frequency magnetic field (7 mT, 40 Hz) used in magnetotherapy alters oxidative balance in rat brain after 10 days of exposure. The 30 min/day exposure condition was associated with increased lipid peroxidation, while the 60 min/day condition was…

[Time effect of sinusoidal electromagnetic field on enhancing the maturation and mineralization of osteoblasts in vitro].

RF Safe Research Library Jan 1, 2011 NEUTRAL LOW

This in vitro study exposed newborn rat calvarial osteoblasts to 50 Hz sinusoidal electromagnetic fields at 1.8 mT for different daily exposure times (0.5–3.0 h). The authors report inhibited osteoblast proliferation at longer exposure times, alongside increased differentiation markers (ALP…

Electric field analysis of breast tumor cells.

RF Safe Research Library Jan 1, 2011 NEUTRAL LOW

This paper reports a MAXWELL 3D simulation study of electric field distribution in a tissue/tumor model relevant to electrical-pulse-mediated drug delivery. The authors report lower electric field strength in tumor tissue compared with normal cells. They interpret this as potentially increasing…

[Psychophysiological indicators for children using mobile phones. Communication 1. Current state of the problem].

RF Safe Research Library Jan 1, 2011 CONCERN UNKNOWN

This article reviews epidemiological and experimental evidence on electromagnetic radiation from mobile phones in humans and animals. It focuses in detail on potential effects on children. The abstract reports that children are more sensitive to this type of exposure than adults.

A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This paper reports the development of a 15-channel transmit-receive RF coil for 7 T human brain MRI, using a hybrid decoupling approach to support element placement along three axes. The design is presented as enabling B1+ shimming and parallel imaging acceleration in three dimensions, with…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination,…

Selenium supplementation ameliorates static magnetic field-induced disorders in antioxidant status in rat tissues.

RF Safe Research Library Jan 1, 2011 CONCERN MEDIUM

This rat study examined whether selenium supplementation modifies antioxidant-related changes associated with sub-acute static magnetic field exposure. The authors report that SMF exposure altered tissue selenium levels and antioxidant enzyme activities in a tissue-specific manner, including…

Impact of a pulsed electric field on damage of plant tissues: effects of cell size and tissue electrical conductivity.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This experimental and modeling study examined pulsed electric field (PEF) permeabilization in several fruit and vegetable tissues at 293 K using 1000 μs pulses and field strengths of 400 and 1000 V·cm(-1). While electroporation theory predicts greater damage in tissues with larger cells, the…

Influence of pulsed electric field treatments on the volatile compounds of milk in comparison with pasteurized processing.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

The paper evaluates how pulsed electric field (PEF) processing affects milk volatile compounds compared with HTST pasteurization (75 °C, 15 s). GC-MS detected 37 volatiles and reported some compositional differences between PEF and pasteurized milk, including increased aldehydes and lower methyl…

Increased blood oxygen level-dependent (BOLD) sensitivity in the mouse somatosensory cortex during electrical forepaw stimulation using a cryogenic radiofrequency probe.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This engineering-focused mouse fMRI study evaluated a 400-MHz cryogenic RF probe (CryoProbe) versus a conventional room-temperature surface coil during electrical forepaw stimulation. The CryoProbe increased image SNR and temporal SNR and reduced temporal noise compared with the room-temperature…

Reduction of implant RF heating through modification of transmit coil electric field.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with…

Impact of a static magnetic field on the electricity production of Shewanella-inoculated microbial fuel cells.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This study investigated how exposure to a static magnetic field affects electricity production in Shewanella-inoculated microbial fuel cells across different reactor configurations. A 100 mT field was reported to increase maximum voltage and the effect was described as immediate and reversible,…

Transient and steady-state magnetic fields induce increased fluorodeoxyglucose uptake in the rat hindbrain.

RF Safe Research Library Jan 1, 2011 CONCERN MEDIUM

This animal PET study examined whether a weak 60-Hz magnetic field alters brain glucose utilization in rats. The abstract reports increased FDG uptake in hindbrain voxels when a 2.5-G field was oriented orthogonally to the sagittal plane, but not when field direction varied randomly. Distinct…

Human keratinocytes in culture exhibit no response when exposed to short duration, low amplitude, high frequency (900 MHz) electromagnetic fields in a reverberation chamber.

RF Safe Research Library Jan 1, 2011 REASSURANCE MEDIUM

This in vitro study exposed normal human epidermal keratinocytes to non-thermal 900 MHz electromagnetic fields in a mode-stirred reverberation chamber under two short-duration conditions. Microarray analysis found only limited gene modulation (20 genes) with small expression ratios and no shared…

Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.

RF Safe Research Library Jan 1, 2011 NEUTRAL MEDIUM

This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at…

Page 69 / 79
Prev Next