Reduced exposure to microwave radiation by rats: frequency specific effects.

PAPER pubmed Progress in clinical and biological research 1988 Animal study Effect: harm Evidence: Low

Abstract

Previous research has shown that SAR "hotspots" are induced within the laboratory rat and that the resulting thermal hotspots are not entirely dissipated by bloodflow. Two experiments were conducted to determine if hotspot formation in the body and tail of the rat, which is radiation frequency specific, would have behavioral consequences. In the first experiment rats were placed in a plexiglas cage one side of which, when occupied by the rat, commenced microwave radiation exposure; occupancy of the other side terminated exposure. Groups of rats were tested during a baseline period to determine the naturally preferred side of the cage. Subsequent exposure to 360-MHz, 700-MHz or 2450-MHz microwave radiation was made contingent on preferred-side occupancy. A significant reduction in occupancy of the preferred side of the cage, and hence, microwaves subsequently occurred. Reduced exposure to 360-MHz and 2450-MHz microwaves at 1, 2, 6 and 10 W/kg were significantly different from 700-MHz microwaves. In the second experiment semichronic exposures revealed the threshold for reduced exposure of 2450-MHz microwaves to be located between whole-body SAR's of 2.1 and 2.8 W/kg.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
harm
Population
Laboratory rats
Sample size
Exposure
microwave · semichronic (second experiment); baseline and subsequent contingent exposure periods (first experiment)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Rats reduced occupancy of a preferred cage side when occupancy triggered microwave exposure, resulting in reduced exposure. Avoidance/reduced exposure differed by frequency: 360 MHz and 2450 MHz at 1, 2, 6, and 10 W/kg were significantly different from 700 MHz. In semichronic exposures, the threshold for reduced exposure at 2450 MHz was between whole-body SARs of 2.1 and 2.8 W/kg.

Outcomes measured

  • Behavioral avoidance/reduced occupancy of preferred cage side (reduced exposure)
  • Frequency-specific differences in avoidance
  • Threshold whole-body SAR for reduced exposure (2450 MHz)

Limitations

  • Sample size not reported in abstract
  • Exposure duration and detailed protocol parameters not fully described in abstract
  • Outcome is behavioral avoidance rather than direct health endpoints
  • Mechanistic interpretation (hotspots/thermal effects) mentioned but not directly quantified in the abstract
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "microwave",
        "source": null,
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "semichronic (second experiment); baseline and subsequent contingent exposure periods (first experiment)"
    },
    "population": "Laboratory rats",
    "sample_size": null,
    "outcomes": [
        "Behavioral avoidance/reduced occupancy of preferred cage side (reduced exposure)",
        "Frequency-specific differences in avoidance",
        "Threshold whole-body SAR for reduced exposure (2450 MHz)"
    ],
    "main_findings": "Rats reduced occupancy of a preferred cage side when occupancy triggered microwave exposure, resulting in reduced exposure. Avoidance/reduced exposure differed by frequency: 360 MHz and 2450 MHz at 1, 2, 6, and 10 W/kg were significantly different from 700 MHz. In semichronic exposures, the threshold for reduced exposure at 2450 MHz was between whole-body SARs of 2.1 and 2.8 W/kg.",
    "effect_direction": "harm",
    "limitations": [
        "Sample size not reported in abstract",
        "Exposure duration and detailed protocol parameters not fully described in abstract",
        "Outcome is behavioral avoidance rather than direct health endpoints",
        "Mechanistic interpretation (hotspots/thermal effects) mentioned but not directly quantified in the abstract"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "rats",
        "microwave radiation",
        "frequency-specific effects",
        "behavior",
        "avoidance",
        "occupancy",
        "SAR",
        "360 MHz",
        "700 MHz",
        "2450 MHz",
        "hotspots",
        "thermal"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.