Archive

7 posts

Filters: tag: Compliance Assessment Clear

Intercomparisons of computed epithelial/absorbed power density & temperature rise in anatomical human face models under localized exposures at 10 & 30 GHz

Research RF Safe Research Library Jan 1, 2025

This dosimetry intercomparison evaluated epithelial/absorbed power density and temperature rise in two high-resolution anatomical human face models under localized antenna exposures at 10 and 30 GHz. The study reports a statistical correlation between spatially averaged absorbed power density and temperature rise…

Analysis of Actual Transmitted Power from Hundreds of 5G FR2 Radio Base Stations over One Month in Urban Areas in Japan

Research RF Safe Research Library Jan 1, 2025

This exposure/compliance assessment study collected 5- and 30-minute transmitted power data over one month from more than 400 5G FR2 beamforming base stations in urban Japan to evaluate the IEC 62232:2025 “actual maximum approach.” All measured transmitted powers were below configured maxima, with 30-minute averaged…

5G EMF Exposure at 3.6 GHz in Greece Using Data From Frequency-Selective Monitoring Sensors

Research RF Safe Research Library Jan 1, 2025

This exposure-assessment study analyzed two years of continuous frequency-selective monitoring from 13 sensors in the five largest cities in Greece, focusing on the 3.6 GHz 5G band. It reports a gradual increase in 3.6 GHz environmental EMF levels over time and greater variability than legacy cellular bands, with…

Improved Calculation Method of Coupling Factors for Low-Frequency Wireless Power Transfer Systems.

Research RF Safe Research Library Jan 1, 2021

This engineering/methods study addresses computational artifacts that can affect coupling factor calculations for localized EMF exposure assessment in IEC 62311/62233, particularly below 10 MHz. The authors propose using the 99.99th percentile rather than the maximum internal quantity to mitigate abnormal peaks from…

A statistical analysis for RF-EMF exposure levels in sensitive land use: A novel study in Greek primary and secondary education schools.

Research RF Safe Research Library Jan 1, 2020

This exposure assessment estimated mean RF-EMF levels in Greek primary and secondary schools located in urban environments. Using a random sample of 492 schools, the reported mean electric field strength across 27 MHz–3 GHz was 0.42 V/m with a 95% CI of 0.4024–0.4395 V/m. The authors conclude the measured levels were…

The role of the location of personal exposimeters on the human body in their use for assessing exposure to the electromagnetic field in the radiofrequency range 98-2450 MHz and compliance analysis: evaluation by virtual measurements

Research RF Safe Research Library Jan 1, 2015

This study used numerical modeling with a human body model to evaluate how the placement of a single body-worn personal exposimeter affects RF electric-field measurements in the 98–2450 MHz range. Across 256 simulated exposure scenarios, the body substantially altered measured values compared with the unperturbed…

Occupational exposure to intermediate frequency and extremely low frequency magnetic fields among personnel working near electronic article surveillance systems

Research RF Safe Research Library Jan 1, 2014

This workplace measurement study assessed intermediate frequency (IF) and extremely low frequency (ELF) magnetic field exposure among cashiers working near electronic article surveillance (EAS) systems in Finnish stores. Typical seated exposures were reported as well below limits, but short-term exceedances of ICNIRP…