Archive

2 posts

Showing results for: phantom experiment

Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change.

Research RF Safe Research Library Jan 1, 2016

This engineering study evaluates how anatomical/geometric differences affect MRI RF safety metrics. Simulations and a bovine-phantom experiment found that similar transmit B-field patterns can coincide with notably different peak SAR and temperature rise. The authors highlight challenges in using…

Reduction of implant RF heating through modification of transmit coil electric field.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…

Page 1 / 1