In situ electric field dosimetry analysis for powerline frequency peripheral nerve magnetic stimulation
Research
RF Safe Research Library
Jan 1, 2025
This study used computational dosimetry to analyze induced electric fields in a realistic human body model for a 60 Hz magnetic-field exposure system targeting the leg. Simulations indicated high EF intensities in several leg nerves and modeled conditions consistent with possible peripheral nerve stimulation. The MRG…
Sinusoidal Extremely Low-Frequency Electromagnetic Stimulation (ELF-EMS) Promotes Angiogenesis In Vitro.
Research
RF Safe Research Library
Jan 1, 2025
This in vitro/in ovo study examined whether extremely low-frequency electromagnetic stimulation (ELF-EMS; 13.5 mT at 10 and 60 Hz) activates angiogenic processes under homeostatic conditions. In human microvascular endothelial cells, ELF-EMS increased proliferation, migration/transmigration, and tube formation, with…
Extremely Low-Frequency Electromagnetic Stimulation (ELF-EMS) Improves Neurological Outcome and Reduces Microglial Reactivity in a Rodent Model of Global Transient Stroke.
Research
RF Safe Research Library
Jan 1, 2023
This animal and laboratory study evaluated extremely low-frequency electromagnetic stimulation (ELF-EMS) in a rodent ischemia-reperfusion stroke model and related in vitro/slice experiments. The authors report improved neurological and behavioral outcomes, increased neuronal survival, and reduced glial/microglial…
Exploring the form- And time-dependent effect of low-frequency electromagnetic fields on maintenance of hippocampal long-term potentiation.
Research
RF Safe Research Library
Jan 1, 2020
This in vitro study developed an MEA-compatible magnetic stimulation device to deliver low-frequency EMFs during hippocampal LTP experiments without interrupting induction. The authors report that sine-wave LF-EMFs applied post-induction or as priming reduced fEPSP slope during LTP maintenance, with stronger effects…
Non-Ionizing Radiation in Swedish Health Care-Exposure and Safety Aspects.
Research
RF Safe Research Library
Jan 1, 2019
This review describes non-ionizing radiation (EMF and optical radiation) methods used in Swedish health care and considers anticipated exposure levels and potential hazards. The authors report that acute effects cannot be ruled out for MRI, transcranial magnetic stimulation, and electrosurgery, and that optical…
Acute exposure to high-induction electromagnetic field affects activity of model peripheral sensory neurons.
Research
RF Safe Research Library
Jan 1, 2018
This in vitro study examined acute low-frequency electromagnetic field (LF-EMF) exposure using high-induction magnetic stimulation in F11 cells, a dorsal root ganglia neuron-derived model of peripheral sensory neurons. Short-term exposure (
Influence of the on-line ELF-EMF stimulation on the electrophysiological properties of the rat hippocampal CA1 neurons in vitro.
Research
RF Safe Research Library
Jan 1, 2017
This paper describes an on-line ELF magnetic stimulation setup and evaluates coil field distribution using COMSOL simulations alongside physical measurements. The authors report that modeled and measured magnetic flux densities were similar, and that stimulation induced sodium channel currents and fEPSPs in rat…
Synchronization of neuron population subject to steady DC electric field induced by magnetic stimulation.
Research
RF Safe Research Library
Jan 1, 2013
This paper investigates, in an interneuronal network model, how a steady DC electric field induced by magnetic stimulation affects network coherence and synchronization. The authors report that coherence can exhibit a peak or plateau across a defined range of induced field values. Effects varied by network topology…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
In vitro magnetic stimulation of pig phrenic nerve with transverse and longitudinal induced electric fields: analysis of the stimulation site.
Research
RF Safe Research Library
Jan 1, 2009
This in vitro study analyzed where magnetic stimulation activates pig phrenic nerves when induced electric fields are oriented longitudinally versus transversely to the nerve trunk. Longitudinal-field stimulation localized activation near the negative peak of the spatial derivative of the longitudinal electric field,…
Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.
Research
RF Safe Research Library
Jan 1, 2009
This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…
Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).
Research
RF Safe Research Library
Jan 1, 2008
This engineering-focused conference paper proposes figures of merit to evaluate deep-brain transcranial magnetic stimulation (dTMS) coil designs, focusing on depth penetration, scalp stimulation, focality, and energy. It analyzes circular crown and C-core coils and reports reduced electric-field attenuation with…