Intercomparisons of computed epithelial/absorbed power density & temperature rise in anatomical human face models under localized exposures at 10 & 30 GHz
Research
RF Safe Research Library
Jan 1, 2025
This dosimetry intercomparison evaluated epithelial/absorbed power density and temperature rise in two high-resolution anatomical human face models under localized antenna exposures at 10 and 30 GHz. The study reports a statistical correlation between spatially averaged absorbed power density and temperature rise…
Assessment of Electromagnetic Field Exposure from Multiple Sources Simultaneously in the High- Frequency Range Based on Safety Standards
Research
RF Safe Research Library
Jan 1, 2025
This conference paper proposes a method to assess combined EMF exposure from multiple simultaneous high-frequency sources using a normalized exposure ratio based on ICNIRP 2020 guidelines. It emphasizes a current gap in standardized absorbed power density (Sab) measurement above 10 GHz and proposes incident power…
Model Variability in Assessment of Human Exposure to Radiofrequency Fields
Research
RF Safe Research Library
Jan 1, 2025
This review examines how variability in computational dosimetry models affects assessment of human RF exposure from MHz to terahertz frequencies, focusing on SAR, absorbed power density, and temperature rise. It reports that anatomical scaling and model choices can drive meaningful differences in predicted SAR…
Behaviour and reproduction of Drosophila melanogaster exposed to 3.6 GHz radio-frequency electromagnetic fields
Research
RF Safe Research Library
Jan 1, 2025
This animal study assessed whether 3.6 GHz RF-EMF exposure affects behaviour and reproduction in adult Drosophila melanogaster, using micro-CT-based digital-twin dosimetry and numerical simulations. It reports no significant changes in locomotor activity after 5 days at 5.4–9 V/m and no effect on fecundity over 48…
Assessment of spatial-average absorbed power density and peak temperature rise in skin model under localized electromagnetic exposure
Research
RF Safe Research Library
Jan 1, 2025
This numerical dosimetry study modeled localized RF exposure (3–30 GHz) in multi-layer human skin constructs including skin, fat, and muscle, with an added synthetic blood vessel model. Vascular modeling had negligible impact on peak spatial-averaged absorbed power density and a modest impact on peak temperature rise…
Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz
Research
RF Safe Research Library
Jan 1, 2025
This paper presents a traceable experimental dosimetry method to measure absorbed power density (APD) from body-mounted wireless devices at frequencies above 10 GHz. It combines a miniaturized broadband probe, a composite skin-equivalent phantom, and reconstruction/calibration procedures, with validation using…
Impact of Anthropomorphic Shape and Skin Stratification on Absorbed Power Density in mmWaves Exposure Scenarios
Research
RF Safe Research Library
Jan 1, 2025
This dosimetry study used FDTD simulations at 28 GHz to evaluate how skin stratification and anthropomorphic modeling affect absorbed power density (APD) estimates. APD was higher with stratified skin than with homogeneous skin for a wearable patch antenna (16%–30% higher), while plane-wave differences were smaller (