Archive

152 posts

Showing results for: measurement

Validity of at home model predictions as a proxy for personal exposure to radiofrequency electromagnetic fields from mobile phone base stations

Research RF Safe Research Library Jan 1, 2015

This exposure-assessment study compared modeled at-home RF-EMF from mobile phone base stations (NISMap) with 24-hour personal measurements in 93 Dutch participants. Correlations were low to moderate, with better agreement for time spent at home than for the full 24-hour period. While modeled estimates could rank…

Near-field radiofrequency electromagnetic exposure assessment

Research RF Safe Research Library Jan 1, 2015

This paper presents a near-field RF exposure assessment method comparing standard SAR estimation from E-field measurements in tissue-simulating liquid with a proposed approach based on incident H-field measurements. Experiments were conducted at 900, 1800, and 2450 MHz using dipole antennas and a flat phantom, with…

Strain in YBCO Double-Pancake Coil With Stainless Steel Overband Under External Magnetic Field.

Research RF Safe Research Library Jan 1, 2015

This engineering study evaluates mechanical hoop strain in a YBCO coated-conductor double-pancake coil intended for a high-field HTS insert in an NMR magnet. The authors present experimental strain-gauge measurements and analytical stress/strain calculations for a coil operated with and without a stainless steel…

Electromagnetic field exposure assessment in Europe radiofrequency fields (10 MHz-6 GHz).

Research RF Safe Research Library Jan 1, 2015

This paper provides an overview of published RF EMF exposure measurements in Europe and characterizes population exposure patterns. Across included spot and long-term measurement studies, reported mean electric field strengths were generally low (mostly

RF Shielded Hat for Protecting Cameraman from EMF Exposure

Research RF Safe Research Library Jan 1, 2014

The paper describes the development of RF-shielded hats using a microwave absorbing sheet intended to reduce EMF exposure to a cameraman’s head. Three hat designs are described, and measurements are planned/performed in an anechoic chamber using a wireless video camera operating around 1.9–2.7 GHz, including a 2.45…

Occupational exposure to intermediate frequency and extremely low frequency magnetic fields among personnel working near electronic article surveillance systems

Research RF Safe Research Library Jan 1, 2014

This workplace measurement study assessed intermediate frequency (IF) and extremely low frequency (ELF) magnetic field exposure among cashiers working near electronic article surveillance (EAS) systems in Finnish stores. Typical seated exposures were reported as well below limits, but short-term exceedances of ICNIRP…

No effects of power line frequency extremely low frequency electromagnetic field exposure on selected neurobehavior tests of workers inspecting transformers and distribution line stations versus controls

Research RF Safe Research Library Jan 1, 2014

This study evaluated whether occupational 50 Hz ELF-EMF exposure near transformers and distribution power lines affects performance on several computer-based neurobehavior tests. Spot measurements found some electric-field locations above a national occupational standard, while all magnetic-field spots were below the…

Extremely low-frequency magnetic fields of transformers and possible biological and health effects

Research RF Safe Research Library Jan 1, 2014

This study measured leakage extremely low-frequency (ELF) magnetic fields around a transformer located on the bottom floor of a three-floor apartment building in Istanbul. The measurements were evaluated against international exposure standards, and the authors report exposures higher than the IARC threshold magnetic…

Occupational exposure to electromagnetic fields of uninterruptible power supply industry workers

Research RF Safe Research Library Jan 1, 2014

This workplace exposure assessment reports extensive spot measurements of ELF electric and magnetic fields in a UPS factory across test areas, production lines, and power substations. The highest fields were observed in test areas (up to 992.0 V/m and 215.6 µT). The authors state that measured levels were below…

Extremely Low Frequency Electromagnetic Field from Convective Air Warming System on Temperature Selection and Distance.

Research RF Safe Research Library Jan 1, 2014

This study measured extremely low frequency electromagnetic field (ELF-EMF) emitted by a convective air warming (forced air warmer) device at different temperature settings and distances. Reported ELF-EMF levels increased with closer proximity and higher temperature settings, with mean values around 18 mG at 30 cm.…

Electric field enhancement and far-field radiation pattern of the nanoantenna with concentric rings.

Research RF Safe Research Library Jan 1, 2014

This engineering study evaluates a nanoantenna design that combines concentric gold rings with a directivity-enhanced Raman scattering structure. Using finite-difference time-domain simulations and SERS measurements on fabricated devices with thiophenol, the authors report stronger electric field enhancement,…

Assessment of extremely low frequency magnetic field exposure from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2014

This paper reports extremely low frequency (ELF) magnetic flux density measurements from 47 GSM mobile phones, collected to support exposure classification in the MOBI-KIDS epidemiological study. At 25 mm, maximum resultant magnetic flux density at 217 Hz had a geometric mean of 221 nT, and inclusion of harmonics…

Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam.

Research RF Safe Research Library Jan 1, 2014

This exposure assessment study used portable exposure meters to characterize variability and repeatability of mobile phone base station RF-EMF measurements in urban areas of Basel and Amsterdam. Reported exposure levels varied by area type and city, with downtown/business areas showing higher ranges than residential…

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors.

Research RF Safe Research Library Jan 1, 2014

This study tested whether radiofrequency emissions from a ringing GSM mobile phone affect home blood glucose monitor readings. Among 45 female nondiabetic students, the group measured in the presence vs absence of a ringing phone showed larger changes between two readings than a repeat-measurement control group…

Specific absorption rate variation in a brain phantom due to exposure by a 3G mobile phone: problems in dosimetry.

Research RF Safe Research Library Jan 1, 2013

This paper describes a SAR measurement system for a 3G mobile phone (1718.5 MHz) using brain phantom material in a Perspex box sized to a small rat volume, with induced fields measured at multiple locations. SAR was computed from induced-field measurements and also estimated experimentally via temperature rise, with…

Sensitivity enhancement of Faraday effect based heterodyning fiber laser magnetic field sensor by lowering linear birefringence.

Research RF Safe Research Library Jan 1, 2013

This engineering study describes a method to improve the sensitivity of Faraday-effect-based heterodyning fiber laser sensors for magnetic field measurement. It reports an inverse relationship between magnetic-field sensitivity and intra-cavity linear birefringence, supported by theory and experimental birefringence…

[Measurement and assessment of electromagnetic fields near radiophones in line with provisions of European Directive 2013/35/EU and Polish labour law].

Research RF Safe Research Library Jan 1, 2013

This exposure assessment measured unperturbed electric fields near antennas of 50 portable radiophones used by rescue and uniformed services. Occupational exposure-level field strengths (per Polish OSH safety-zone criteria) occurred tens of centimeters from antennas, and Directive 2013/35/EU action levels were…

Electric field in a plasma channel in a high-pressure nanosecond discharge in hydrogen: a coherent anti-stokes Raman scattering study.

Research RF Safe Research Library Jan 1, 2013

This experimental study measured the electric field inside a plasma channel formed during a high-pressure nanosecond discharge in hydrogen using coherent anti-Stokes Raman scattering. The authors report root-mean-square electric field intensities up to 30 kV/cm in the plasma channel. Polarization measurements…

The movement of actin-myosin biomolecular linear motor under AC electric fields: an experimental study.

Research RF Safe Research Library Jan 1, 2013

This in vitro experimental study examined how an AC electric field influences actin filament (F-actin) movement on a myosin-coated substrate. The authors report that the field induces electro-orientation torque that aligns movement perpendicular toward electrode edges, with alignment increasing with field strength.…

Citrate-capped gold nanoparticle electrophoretic heat production in response to a time-varying radiofrequency electric-field.

Research RF Safe Research Library Jan 1, 2012

This in vitro study examines RF-induced heat production in citrate-capped gold nanoparticle suspensions while minimizing confounding Joule heating from ionic buffers. It reports size-dependent heating detectable only for ≤10 nm particles, with heating scaling with concentration and surface area and being attenuated…

Effects of radiofrequency radiation on human ferritin: an in vitro enzymun assay.

Research RF Safe Research Library Jan 1, 2012

This in vitro study tested whether 900 MHz GSM mobile phone radiation affects ferritin measurements in human serum wells. Exposed wells (30 minutes, speech-mode phone) showed a statistically significant decrease in ferritin compared with unexposed controls. The authors propose RF exposure may influence…

Removal of earth's magnetic field effect on magnetoelastic resonance sensors by an antisymmetric bias field.

Research RF Safe Research Library Jan 1, 2012

This engineering study addresses measurement error in magnetoelastic resonance sensors caused by Earth's magnetic field. The authors present an antisymmetric magnetic bias field approach and compare the ribbon response to external perturbation fields against a conventional design. They report a 77% reduction in the…

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.

Research RF Safe Research Library Jan 1, 2011

This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

← Prev Page 5 / 7 Next →