Archive

98 posts

Showing results for: pulsed

Pulsed electric field-assisted modification of pectin from sugar beet pulp.

Research RF Safe Research Library Jan 1, 2013

This engineering-focused study evaluates pulsed electric field (PEF)-assisted, solvent-free modification of pectin from sugar beet pulp. The authors report that degree of esterification increased with greater PEF intensity and energy input, with supporting evidence from FT-IR, X-ray diffraction, and NMR. Modified…

Pulsed radiofrequency in peripheral posttraumatic neuropathic pain: A double blind sham controlled randomized clinical trial.

Research RF Safe Research Library Jan 1, 2012

This double-blind, randomized, sham-controlled trial evaluated pulsed radiofrequency applied to injured peripheral nerves for peripheral posttraumatic neuropathic pain. Among 43 analyzed participants, PRF did not show statistically significant benefit over sham for pain reduction at 3 months, nor for neuropathic pain…

Analysis of circular wave packets generated by pulsed electric fields.

Research RF Safe Research Library Jan 1, 2012

This physics study analyzes circular wave packets in high Rydberg states produced by applying a pulsed electric field to extreme Stark states. It reports a position-dependent energy gradient that creates a correlation between principal quantum number and spatial coordinate, which appears insensitive to the initial…

[The problem of participation of different brain regions in the reactions to the low-intensity magnetic and electromagnetic field exposure].

Research RF Safe Research Library Jan 1, 2012

This animal experiment assessed integral and pulsed bioelectric activity across rabbit brain regions during exposure to low-intensity magnetic and electromagnetic fields. The authors report that brain-region participation in CNS reactions varied across exposure parameters and conditions and depended strongly on…

Nanosecond pulse electric field activation of platelet-rich plasma reduces myocardial infarct size and improves left ventricular mechanical function in the rabbit heart.

Research RF Safe Research Library Jan 1, 2012

This animal and in vitro study evaluated nanosecond pulsed electric fields (nsPEF) as a nonchemical method to activate platelet-rich plasma (PRP) for cardioprotection. In rabbits undergoing brief coronary occlusion followed by reperfusion, PRP injection into ischemic myocardium was associated with reduced infarct…

Comparison of 2 methods of non-invasive treatment between transcutaneous electrical stimulation and pulsed electromagnetic field stimulation as replacement of invasive manual acupuncture.

Research RF Safe Research Library Jan 1, 2012

This study compared two non-invasive acupoint stimulation methods—TEAS and PEMF—as alternatives to manual acupuncture for recovery from exercise-induced muscle fatigue. Using 2 Hz stimulation (PEMF magnetic flux 30.92 mT), the authors report faster recovery of EMG median frequency and improved peak torque recovery in…

Peripheral pulsed electromagnetic fields may reduce the placebo effect in migraine patients that do not respond to the sham intervention in a randomized, placebo-controlled, double-blind, cross-over clinical trial.

Research RF Safe Research Library Jan 1, 2012

This randomized, placebo-controlled, double-blind, cross-over trial evaluated a wrist-applied PEMF bracelet in 18 migraine patients and examined possible modulation of placebo effects. In the overall group, both PEMF and placebo were associated with similar reductions in migraine frequency and intensity. The authors…

Short-term effects of pulsed radiofrequency on chronic refractory cervical radicular pain.

Research RF Safe Research Library Jan 1, 2011

This small clinical study evaluated pulsed radiofrequency applied to the cervical dorsal root ganglion in patients with chronic refractory cervical radicular pain. Pain (VAS) and disability (NDI) improved over 3 months, with most patients reporting ≥50% pain relief and satisfaction at follow-up. No adverse effects…

Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.

Research RF Safe Research Library Jan 1, 2011

This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…

Would pulsed radiofrequency applied to different anatomical regions have effective results for chronic pain treatment?

Research RF Safe Research Library Jan 1, 2011

This retrospective cross-sectional study evaluated pulsed radiofrequency (PRF) for chronic pain in patients who did not respond to conventional treatment. Across 24 patients treated at different anatomical regions, 66.7% reportedly achieved at least a 50% reduction in VAS pain scores over a mean follow-up of 8.5…

Impact of a pulsed electric field on damage of plant tissues: effects of cell size and tissue electrical conductivity.

Research RF Safe Research Library Jan 1, 2011

This experimental and modeling study examined pulsed electric field (PEF) permeabilization in several fruit and vegetable tissues at 293 K using 1000 μs pulses and field strengths of 400 and 1000 V·cm(-1). While electroporation theory predicts greater damage in tissues with larger cells, the authors report this…

Influence of pulsed electric field treatments on the volatile compounds of milk in comparison with pasteurized processing.

Research RF Safe Research Library Jan 1, 2011

The paper evaluates how pulsed electric field (PEF) processing affects milk volatile compounds compared with HTST pasteurization (75 °C, 15 s). GC-MS detected 37 volatiles and reported some compositional differences between PEF and pasteurized milk, including increased aldehydes and lower methyl ketones with PEF.…

Disintegration efficiency of pulsed electric field induced effects on onion (Allium cepa L.) tissues as a function of pulse protocol and determination of cell integrity by ¹H-NMR relaxometry.

Research RF Safe Research Library Jan 1, 2010

This experimental study examined how pulsed electric field (PEF) processing parameters affect cell membrane rupture in onion tissue disks, using ion leakage as the primary integrity measure. Disintegration efficiency increased with field strength up to 500 V/cm and varied with pulse width, pulse number, and…

Critical electric field strengths of onion tissues treated by pulsed electric fields.

Research RF Safe Research Library Jan 1, 2010

This experimental study examined how pulsed electric fields affect onion tissue integrity and texture across different field strengths and pulse counts. It reports distinct critical field strengths for plasma membrane versus tonoplast membrane breakdown, with higher thresholds needed for tonoplast disruption. Effects…

High-intensity pulsed electric fields processing parameters affecting polyphenoloxidase activity of strawberry juice.

Research RF Safe Research Library Jan 1, 2010

This study evaluated high-intensity pulsed electric fields (HIPEF) as a processing method to inactivate polyphenoloxidase (PPO) in strawberry juice. Using response surface methodology at a constant electric field of 35 kV/cm, the authors report strong PPO reductions across tested parameter ranges. Bipolar mode,…

The use of pulsed radiofrequency treatment for chronic benign pancreatitis pain.

Research RF Safe Research Library Jan 1, 2009

This paper reports on pulsed radiofrequency treatment as an interventional approach for pain due to chronic benign pancreatitis. The authors describe their experience in two patients and characterize the technique as minimally neurodestructive and potentially able to reduce pain perception by altering nerve…

Evaluation of the efficacy of pulsed electromagnetic field in the management of patients with diabetic polyneuropathy.

Research RF Safe Research Library Jan 1, 2009

This randomized controlled trial evaluated low-power, low-frequency pulsed electromagnetic field (PEMF) therapy at 600 Hz and 800 Hz as an adjunct treatment for diabetic polyneuropathy. Thirty participants were randomized to 600 Hz PEMF, 800 Hz PEMF, or usual medical treatment for 12 days. The abstract reports…

Combined effect of temperature and pulsed electric fields on apple juice peroxidase and polyphenoloxidase inactivation.

Research RF Safe Research Library Jan 1, 2008

This laboratory study evaluated pulsed electric fields (PEF) combined with preheating to inactivate peroxidase (POD) and polyphenoloxidase (PPO) in freshly prepared apple juice. The highest reported inactivation occurred with preheating to 50°C and PEF at 40 kV/cm for 100 μs, exceeding the reductions seen with…

[Fluorescence spectra analysis of papain treated by pulsed electric field].

Research RF Safe Research Library Jan 1, 2007

This in vitro study used fluorescence excitation, emission, and polarization spectra to assess structural changes in papain after pulsed electric field (PEF) treatment. Under the reported PEF conditions (50 kV/cm, 1500 Hz, 40 µs pulses, 19,800 pulses), papain activity decreased by 56.5%. Spectral changes (increased…

Comparison of the effects of continuous and pulsed mobile phone like RF exposure on the human EEG.

Research RF Safe Research Library Jan 1, 2007

This study tested whether GSM-like RF exposure affects resting human EEG, focusing on alpha band power and non-linear EEG features. Using a fully counterbalanced cross-over design with 12 participants and a dipole antenna intended to better resemble handset exposure, the authors found no changes after 15 minutes of…

Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study.

Research RF Safe Research Library Jan 1, 2007

This randomized animal study tested whether pulsed electromagnetic field (PEMF)-induced vibration affects orthodontic tooth movement produced by magnetic and/or mechanical forces. Forty-four Wistar rats were exposed to PEMF-induced vibration or normal atmosphere while tooth movement was induced using magnets and/or…

Physics and biology of mobile telephony

Research RF Safe Research Library Jan 1, 2000

This review argues that current mobile-telephony safety guidelines address excessive microwave heating but may not account for potential non-thermal influences of low-intensity, pulsed radiation. It highlights an asserted oscillatory similarity between pulsed microwave signals and certain electrochemical activities…

The effect of pulsed and sinusoidal magnetic fields on the morphology of developing chick embryos

Research RF Safe Research Library Jan 1, 1997

This animal study reports results from five experimental campaigns over five years examining weak magnetic field exposure and morphological abnormalities in White Leghorn chick embryos. Four campaigns reported statistically significant increases in abnormality rates, while one pulsed-field campaign showed only a…

← Prev Page 4 / 4