Theory for nanoparticle retention time in the helical channel of quadrupole magnetic field-flow fractionation.
Research
RF Safe Research Library
Jan 1, 2009
This paper presents a theoretical treatment of nanoparticle retention in quadrupole magnetic field-flow fractionation (QMgFFF) using a helical separation channel. It defines the retention ratio as the ratio of transit times for non-retained versus retained material. Equations are derived for angular and longitudinal…
Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.
Research
RF Safe Research Library
Jan 1, 2009
This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…
Evaluation of the efficacy of pulsed electromagnetic field in the management of patients with diabetic polyneuropathy.
Research
RF Safe Research Library
Jan 1, 2009
This randomized controlled trial evaluated low-power, low-frequency pulsed electromagnetic field (PEMF) therapy at 600 Hz and 800 Hz as an adjunct treatment for diabetic polyneuropathy. Thirty participants were randomized to 600 Hz PEMF, 800 Hz PEMF, or usual medical treatment for 12 days. The abstract reports…
[A preliminary study on role of acid sphingomyelinase in receptor clustering induced by 50-Hz magnetic fields].
Research
RF Safe Research Library
Jan 1, 2009
This in vitro study exposed human amnion (FL) cells to a 50-Hz sinusoidal magnetic field (0.4 mT) for 15 minutes and assessed epidermal growth factor receptor (EGFR) clustering. The authors report that magnetic field exposure induced EGFR clustering, and that this effect was blocked by imipramine, an acid…
[Conclusion: probable and possible futures. MRI with ultra high magnetic field].
Research
RF Safe Research Library
Jan 1, 2009
This narrative piece states that MR neuroimaging does not interfere with brain function and is safe for use in patients and healthy volunteers. It argues that ultra-high-field MRI could substantially improve spatiotemporal resolution, potentially enabling study of brain function at finer scales. It also describes the…
Static magnetic field therapy: a critical review of treatment parameters.
Research
RF Safe Research Library
Jan 1, 2009
This critical review summarizes human research on static magnetic field (SMF) therapy delivered by permanent magnets attached to the skin and evaluates how well studies report SMF dosage and treatment parameters. Across 56 included studies, many did not report essential SMF characteristics (e.g., magnet dimensions,…
Biological effects from electromagnetic field exposure and public exposure standards
Research
RF Safe Research Library
Jan 1, 2008
This review describes public concerns and scientific reports of non-thermal biological effects from low-intensity ELF and RF exposures. It lists multiple health endpoints reported to be associated with ELF and/or RF and highlights the BioInitiative Report’s conclusion that a reasonable suspicion of risk exists at…
Synthesis of polylactic acid-polyglycolic acid blends using microwave radiation.
Research
RF Safe Research Library
Jan 1, 2008
This engineering/materials study describes blending PLLA and PGA using microwave irradiation to produce PLGA-related blends with varying constituent concentrations. The authors report that FTIR, NMR, and DSC measurements indicate blending and cross-linking between the polymers. The abstract does not provide microwave…
Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis.
Research
RF Safe Research Library
Jan 1, 2008
This study compared coronary plaque assessment by 64-slice multislice computed tomography (MSCT) with virtual histology intravascular ultrasound (VH IVUS) in 50 patients. The Agatston score on MSCT correlated moderately with calcium volume measured by VH IVUS, and MSCT plaque categories broadly reflected differences…
Apparent violation of the Wiedemann-Franz law near a magnetic field tuned metal-antiferromagnetic quantum critical point.
Research
RF Safe Research Library
Jan 1, 2008
This paper reports calculations of interlayer electrical and thermal resistivity in a layered metal assuming Fermi-liquid quasiparticles inelastically scattered by two-dimensional antiferromagnetic spin fluctuations. The model yields linear-in-temperature behavior over a broad range and suggests that extrapolations…
Arthroscopic capsular shrinkage for chronic ankle instability with thermal radiofrequency: prospective multicenter trial.
Research
RF Safe Research Library
Jan 1, 2008
This prospective multicenter longitudinal trial evaluated arthroscopic thermal radiofrequency capsular shrinkage for chronic ankle instability in adults who failed conservative therapy. The study reports no clinically relevant improvement in mechanical stability, but substantial and statistically significant…
The effect of postoperative immobilization on the healing of radiofrequency heat probe modified tissue: assessment of tissue length, stiffness, and morphology.
Research
RF Safe Research Library
Jan 1, 2008
This animal study examined how postoperative immobilization affects healing after radiofrequency heat probe shrinkage in rabbit patellar tendons. Tendon length increased across all groups by 8 weeks, but 4 weeks of immobilization resulted in less elongation than free activity. Immobilized groups had reduced…
Health hazards of mobile phones: an Indian perspective.
Research
RF Safe Research Library
Jan 1, 2008
This review-style article provides an overview of mobile phone radiation exposure in India and discusses potential health hazards in terms of thermal and non-thermal effects. It states that usage behaviors such as longer call duration and predominantly one-sided use are described as key risks increasing the…
Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field.
Research
RF Safe Research Library
Jan 1, 2008
This paper presents numerical methods to compute ground-state solutions of spin-1 Bose-Einstein condensates in a uniform magnetic field. The approach uses normalized gradient flow with an additional normalization condition and enforces conservation of total mass and magnetization. The authors compare numerical…
Surface-induced nonlinearities of liquid crystals driven by an electric field.
Research
RF Safe Research Library
Jan 1, 2008
This experimental physics study examines how a static electric field affects the optical nonlinearity of methyl-red doped nematic liquid crystals. The authors report that low voltages below the Fredericks transition threshold can change the optical nonlinearity by orders of magnitude. They state that the data fit a…
Aggregation of magnetic holes in a rotating magnetic field.
Research
RF Safe Research Library
Jan 1, 2008
This laboratory study experimentally examined aggregation of nonmagnetic particles in a magnetic fluid layer under a rotating magnetic field. Particles formed two-dimensional clusters that repeatedly aggregated into larger clusters, producing a broad distribution of cluster sizes. The dynamics were described as…
[Radiofrequency aviation treatment for lingual root obstructive sleep apnea-hypopnea syndrome].
Research
RF Safe Research Library
Jan 1, 2008
This clinical study reports outcomes for 34 patients with mild and median OSAHS treated with a combination of functional endoscopic sinus surgery, UPPP, and radiofrequency ablation (RFA). Over 1 year, polysomnography showed a reduction in AHI and an effective rate of 85.29%. Because RFA was used as an adjunct to…
Use of terahertz electromagnetic radiation for correction of blood rheology parameters in patients with unstable angina under conditions of treatment with isoket, an NO donor.
Research
RF Safe Research Library
Jan 1, 2008
This in vitro study examined terahertz electromagnetic radiation at NO-related spectral frequencies and its effects on blood rheology in patients with unstable angina treated with the NO donor isoket. The abstract reports that irradiated isoket had a better normalizing effect on blood viscosity and erythrocyte…
The effect of MRET polymer compound on SAR values of RF phones.
Research
RF Safe Research Library
Jan 1, 2008
This article describes a hypothesis and experimental testing of an MRET polymer compound applied to RF phones. It reports increased dielectric permittivity in water-based solutions and reduced SAR values in a tissue-simulating phantom head. It also reports no significant change in air measurements of phone signals,…
Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…
Noninvasive radiofrequency field-induced hyperthermic cytotoxicity in human cancer cells using cetuximab-targeted gold nanoparticles.
Research
RF Safe Research Library
Jan 1, 2008
This in vitro study reports that shortwave (MHz-range) RF exposure can induce strong cytotoxicity in EGFR-overexpressing human cancer cells when those cells have internalized cetuximab-targeted gold nanoparticles. Control nanoparticles showed minimal uptake and substantially lower cytotoxicity under RF exposure. An…
Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study addresses interference between induction-heating cookers and an externally coupled transcutaneous energy transmission system for a totally implantable artificial heart. The authors report that magnetic flux from an IH cooker can couple into the TET transformer and affect system performance. A…
In vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI.
Research
RF Safe Research Library
Jan 1, 2008
This Medical Physics article presents a phase-based MRI method to quantify paramagnetic contrast agent concentration by inverting susceptibility-induced magnetic field shifts, aiming to improve arterial input function (AIF) measurement in DCE-MRI. After in vitro validation, the approach was applied in vivo in 14…
[Microstrip antenna design and system research of radio frequency identification temperature sensor].
Research
RF Safe Research Library
Jan 1, 2008
This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…
New functions developed for ICU/CCU remote monitoring system using a 3G mobile phone and evaluations of the system.
Research
RF Safe Research Library
Jan 1, 2008
This conference paper describes development of new functions for an ICU/CCU remote monitoring system that uses a 3G mobile phone. The authors state that evaluations were performed on several different mobile phones and suggest the system has accuracy and real-time performance suitable for hospital adoption. The…