Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields - Practical approach to the requirements of European Directive 2013/35/EU.
Research
RF Safe Research Library
Jan 1, 2018
This study assessed electromagnetic field exposure near common strong EMF sources in medical and industrial workplaces to estimate standard safety distances (SSD) for workers using active implantable medical devices (AIMD). Using measurements near 127 devices, the longest SSDs were reported near dielectric sealers…
The Effects of Exposure to Low Frequency Electromagnetic Fields in the Treatment of Migraine Headache: A Cohort Study.
Research
RF Safe Research Library
Jan 1, 2016
This cohort study followed 114 migraine patients and assessed self-reported use of mobile phones, Wi-Fi devices, and fixed-line telephones as RF-EMF sources. Over a 3-month period, migraine frequency and severity were reported as significantly correlated with higher mobile phone and Wi-Fi use, while fixed-line…
Environmental Radiofrequency Electromagnetic Fields Exposure at Home, Mobile and Cordless Phone Use, and Sleep Problems in 7-Year-Old Children
Research
RF Safe Research Library
Oct 28, 2015
This cohort study of 2,361 seven-year-old children assessed modeled residential/school RF-EMF from base stations, reported indoor sources, and children’s mobile/cordless phone use in relation to parent-reported sleep quality. Most sleep subscales were not associated with base-station RF-EMF, though sleep duration…
Electromagnetic fields (UHF) increase voltage sensitivity of membrane ion channels; possible indication of cell phone effect on living cells.
Research
RF Safe Research Library
Jan 1, 2015
This in vitro study used voltage clamp recordings of single OmpF porin channels in an artificial bilayer to test effects of UHF EMF (910–990 MHz). The authors report frequency-dependent changes in channel gating, with increased gating frequency and voltage sensitivity and a maximum effect at 930 MHz. Conductance was…
Interference between active implanted medical devices and electromagnetic field emitting devices is rare but real: results of an incidence study in a population of physicians in France.
Research
RF Safe Research Library
Jan 1, 2014
This cross-sectional incidence survey used a postal questionnaire to assess physician-observed interference incidents between EMF-emitting devices and active implanted medical devices (AIMDs) in France. Among 1,188 participating physicians, 16% reported AIMD failures, typically of moderate severity but sometimes…
Exposure Knowledge and Risk Perception of RF EMF.
Research
RF Safe Research Library
Jan 1, 2014
This cross-sectional survey study (LEXNET project) examined how subjective exposure knowledge relates to risk perception (RP) for different RF EMF sources. Respondents were more concerned about base stations than other sources. Regression results suggested that most exposure-characteristic features (except distance)…
[Study on atmospheric VOCs in Gongga Mountain base station].
Research
RF Safe Research Library
Jan 1, 2012
This study measured atmospheric VOCs at the Gongga Mountain base station using weekly samples collected in 2007 and analyzed by preconcentration plus GC-MS. It reports mean concentrations of TVOCs and NMHCs, describes VOC composition, and uses PCA-based receptor modeling to attribute sources. The authors report…
Scientific Committee on Emerging and Newly Identified Health Risks
Research
RF Safe Research Library
Jan 1, 2009
This SCENIHR Opinion updates earlier 2009 SCENIHR documents on EMF health effects and research needs, focusing on new information and remaining knowledge gaps. The abstract primarily characterizes sources and patterns of exposure across static, ELF, IF, and RF fields in both public and occupational settings. It notes…
Magnetic field distribution and signal decay in functional mri in very high fields (up to 9.4 T) using monte carlo diffusion modeling.
Research
RF Safe Research Library
Jan 1, 2007
This paper models extravascular MRI signal decay (R2/R2*) as a function of blood oxygenation, vessel geometry, and magnetic field strength up to 9.4 T using Monte Carlo diffusion simulations. It reports different vessel-size dependencies for Hahn-spin-echo versus gradient-recalled-echo relaxation across field…