Archive

453 posts

Showing results for: ROS

Microscopic dynamics of the orientation of a hydrated nanoparticle in an electric field.

Research RF Safe Research Library Jan 1, 2009

This paper uses atomistic simulations to examine how a nonpolar nanoparticle suspended in water reorients under an applied electric field. The authors report that molecular-level effects increase the torque relative to continuum estimates and substantially speed up reorientation above a stated field threshold. The…

Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.

Research RF Safe Research Library Jan 1, 2009

This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…

Mobile phone technology for children with type 1 and type 2 diabetes: a parent survey.

Research RF Safe Research Library Jan 1, 2009

This cross-sectional web-based survey assessed parents' concerns about managing their children's diabetes and their attitudes toward a mobile-phone-integrated glucometer service that could transmit real-time glucose readings. Parents most commonly reported concerns about access to their child's health care provider,…

Survey of ownership and use of mobile phones among medical science students in Yazd.

Research RF Safe Research Library Jan 1, 2009

This cross-sectional survey assessed mobile phone ownership and use patterns among 309 medical science students in Yazd using a self-administered questionnaire. The abstract reports descriptive statistics on daily talking time, music listening, texting, and common locations of phone use. While the paper references…

[Conclusion: probable and possible futures. MRI with ultra high magnetic field].

Research RF Safe Research Library Jan 1, 2009

This narrative piece states that MR neuroimaging does not interfere with brain function and is safe for use in patients and healthy volunteers. It argues that ultra-high-field MRI could substantially improve spatiotemporal resolution, potentially enabling study of brain function at finer scales. It also describes the…

Static magnetic field therapy: a critical review of treatment parameters.

Research RF Safe Research Library Jan 1, 2009

This critical review summarizes human research on static magnetic field (SMF) therapy delivered by permanent magnets attached to the skin and evaluates how well studies report SMF dosage and treatment parameters. Across 56 included studies, many did not report essential SMF characteristics (e.g., magnet dimensions,…

Synthesis of polylactic acid-polyglycolic acid blends using microwave radiation.

Research RF Safe Research Library Jan 1, 2008

This engineering/materials study describes blending PLLA and PGA using microwave irradiation to produce PLGA-related blends with varying constituent concentrations. The authors report that FTIR, NMR, and DSC measurements indicate blending and cross-linking between the polymers. The abstract does not provide microwave…

Arthroscopic capsular shrinkage for chronic ankle instability with thermal radiofrequency: prospective multicenter trial.

Research RF Safe Research Library Jan 1, 2008

This prospective multicenter longitudinal trial evaluated arthroscopic thermal radiofrequency capsular shrinkage for chronic ankle instability in adults who failed conservative therapy. The study reports no clinically relevant improvement in mechanical stability, but substantial and statistically significant…

The effect of postoperative immobilization on the healing of radiofrequency heat probe modified tissue: assessment of tissue length, stiffness, and morphology.

Research RF Safe Research Library Jan 1, 2008

This animal study examined how postoperative immobilization affects healing after radiofrequency heat probe shrinkage in rabbit patellar tendons. Tendon length increased across all groups by 8 weeks, but 4 weeks of immobilization resulted in less elongation than free activity. Immobilized groups had reduced…

[Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].

Research RF Safe Research Library Jan 1, 2008

This engineering study reports spectroscopic determination of net electric field distribution in a dielectric barrier surface glow discharge in low-pressure air. Optical emission spectroscopy was used to infer electric field distribution from the intensity ratio of nitrogen spectral lines at 391.4 nm and 337.1 nm.…

Effect of temperature (-5 to 130 degrees C) and fiber direction on the dielectric properties of beef Semitendinosus at radio frequency and microwave frequencies.

Research RF Safe Research Library Jan 1, 2008

This study measured dielectric properties of beef Semitendinosus across 27, 915, and 1800 MHz and temperatures from -5 to 130 °C using an open-ended coaxial probe. The results indicate that frequency, temperature, and muscle fiber orientation influence dielectric constant, dielectric loss, and calculated penetration…

Adverse effects of excessive mobile phone use.

Research RF Safe Research Library Jan 1, 2008

This cross-sectional questionnaire study surveyed 286 medical students about mobile phone use and health complaints. The abstract reports multiple self-reported symptoms (including impaired concentration, memory disturbances, sleeplessness, fatigue, and headache) and notes that 44.4% of respondents attributed their…

SAR changes in a human head model for plane wave exposure (500 - 2500 MHz) and a comparison with IEEE 2005 safety limits.

Research RF Safe Research Library Jan 1, 2008

This engineering/modeling study derived external electric field values from peak average 10 g SAR in a realistic human head model exposed to plane waves at 500–2500 MHz. The derived fields were compared with IEEE and ICNIRP reference levels across multiple incident directions and polarizations. The authors report…

[Microstrip antenna design and system research of radio frequency identification temperature sensor].

Research RF Safe Research Library Jan 1, 2008

This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…

The effect of GSM-like ELF radiation on the alpha band of the human resting EEG.

Research RF Safe Research Library Jan 1, 2008

This double-blind, counterbalanced cross-over study investigated whether extremely low frequency (DC to at least 40 kHz) fields emitted by GSM handsets affect resting EEG. In 72 healthy volunteers, the authors report a decrease in the alpha band during 20 minutes of ELF exposure in the exposed hemisphere only. They…

A benzene-core trinuclear GdIII complex: towards the optimization of relaxivity for MRI contrast agent applications at high magnetic field.

Research RF Safe Research Library Jan 1, 2008

This chemistry/engineering study reports the synthesis and NMR/MRI-relevant characterization of a trinuclear Gd(III) chelate intended for high-field MRI contrast applications. Using 17O NMR and proton relaxivity across multiple fields and temperatures, the authors infer bishydration, quantify water exchange and…

Microscopic observation of living cells during their exposure to modulated electromagnetic fields.

Research RF Safe Research Library Jan 1, 2008

This paper describes an exposure and microscopy system designed to continuously observe living cells during exposure to modulated RF-EMF similar to mobile phone signals. Using protocols where the same cells serve as controls before and after exposure, the system was validated with endocytosis measurements. Under 900…

Histologic evaluation of thermal capsulorrhaphy of human shoulder joint capsule with monopolar radiofrequency energy during short- to long-term follow-up.

Research RF Safe Research Library Jan 1, 2008

This Level III therapeutic case-control study evaluated shoulder capsule histology after arthroscopic thermal capsulorrhaphy using monopolar radiofrequency energy, with follow-up from 3.5 to 62 months. Mid- and long-term mRFE groups did not differ from controls on several histologic categories (synovial layer, edema,…

[Measurements of professional exposure to ELF fields in some production areas within the territory of Regione Campania and comparison with the action values according to 2004/40/CE Directive].

Research RF Safe Research Library Jan 1, 2007

This occupational exposure assessment measured ELF magnetic fields in 400 workers across 80 work areas in several production sectors in Regione Campania. Measurements were taken continuously over two shifts and processed into RMS magnetic-field values. The authors report no exceedance of the EU 2004/40/CE action…

[Assessment of radiofrequency electromagnetic fields levels in the Taranto area].

Research RF Safe Research Library Jan 1, 2007

This study reports punctual monitoring of RF electromagnetic fields from radiobase stations in the Taranto area, with measurement campaigns conducted from November 2005 to March 2007. Measurements covered 108 transmitting stations across multiple communication technologies within 100 kHz to 3 GHz. Most monitored…

[ELF-MF occupational exposure: repeated measures on workers].

Research RF Safe Research Library Jan 1, 2007

This occupational exposure assessment used personal dosimeters to estimate ELF magnetic field exposure in 543 workers across 9 occupational settings in Emilia-Romagna. Median time-weighted average exposure was 0.14 microT, with tile production showing the highest setting-level TWA. Repeat measurements after 6–9…

[Evaluation of the genotoxicity of the extremely low frequency-magnetic fields (ELF-MF) in workers exposed for professional reasons].

Research RF Safe Research Library Jan 1, 2007

This occupational study assessed whether extremely low frequency magnetic fields (ELF-MF) are associated with genotoxicity using cytogenetic assays in 109 workers. Comparisons across exposure strata, including a highest-exposed subgroup (TWA > 1 microT), found no significant differences in CA, SCE, or MN outcomes.…

Biophoton emission of MDCK cell with hydrogen peroxide and 60 Hz AC magnetic field.

Research RF Safe Research Library Jan 1, 2007

This in vitro study measured biophoton/chemiluminescence emission from MDCK cells after inducing reactive oxygen species with hydrogen peroxide. The authors report that photon emission increased with hydrogen peroxide dose and that photomultiplier tube measurements agreed with fluorescence microscopy observations.…

Use of radiofrequency hepatic parenchymal transection device in hepatic hemangioma resection: early experience and lessons learned.

Research RF Safe Research Library Jan 1, 2007

This retrospective case series reviewed four resections of symptomatic giant cavernous hepatic hemangiomas using an RF-powered multiarray (Habib sealer) for hepatic parenchymal transection. No blood transfusions were required and no major biliary or vascular injuries were observed at 1-year follow-up; one…

Comparison of the effects of continuous and pulsed mobile phone like RF exposure on the human EEG.

Research RF Safe Research Library Jan 1, 2007

This study tested whether GSM-like RF exposure affects resting human EEG, focusing on alpha band power and non-linear EEG features. Using a fully counterbalanced cross-over design with 12 participants and a dipole antenna intended to better resemble handset exposure, the authors found no changes after 15 minutes of…

← Prev Page 18 / 19 Next →