Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.
Research
RF Safe Research Library
Jan 1, 2010
This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…
Spin current pumped by a rotating magnetic field in zigzag graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study models electron spin resonance and spin/charge pumping in zigzag graphene nanoribbons driven by a transverse rotating magnetic field without applied bias. It reports that pumped spin current density increases with ribbon size and rotating-field intensity, and that even-chain ribbons can also…
Anomalous magnetic field dependence of Y Ba(2)Cu(3)O(7 - δ): effect of orthorhombic distortion.
Research
RF Safe Research Library
Jan 1, 2010
This paper presents a theoretical model to investigate the origin of a mixed symmetry pairing state in the high-Tc superconductor YBa2Cu3O7-δ under applied magnetic fields between Hc1 and Hc2. The authors report that the model’s results, and their stated agreement with relevant experimental data, suggest orthorhombic…
Electron dynamics in inhomogeneous magnetic fields.
Research
RF Safe Research Library
Jan 1, 2010
This paper is a review of two-dimensional electron dynamics in microscopically inhomogeneous magnetic fields, focusing on magnetic potentials varying on scales smaller than the mean free path. It covers early work on localization in random magnetic fields, methods to fabricate magnetic potentials, and drift-diffusion…
Quantitative determination of domain distribution in SrTiO3-competing effects of applied electric field and mechanical stress.
Research
RF Safe Research Library
Jan 1, 2010
This neutron diffraction study quantifies how tetragonal structural domains in SrTiO3 redistribute below 105 K under external electric fields and uniaxial mechanical stress. The authors report that electric field and stress act competitively, and that applying both produces complex domain redistribution. The results…
Effect of two length scales on the properties of MgB(2) for arbitrary applied magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This paper analyzes anomalous magnetic-field and temperature dependences observed in MgB(2) superconductivity experiments using a two-order-parameter Ginzburg-Landau theory with two length scales. The authors numerically solve the nonlinear Ginzburg-Landau equations for arbitrary applied fields between Hc1 and Hc2 to…
Spin polarization induced by in-plane electric and magnetic fields in two-dimensional heavy-hole systems.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study uses a nonequilibrium Green function approach to analyze current-induced spin polarization in a two-dimensional heavy-hole system with cubic Rashba spin-orbit coupling under in-plane electric and magnetic fields. The authors report monotonic decreases in longitudinal conductivity with…
An extension of the Czjzek model for the distributions of electric field gradients in disordered solids and an application to NMR spectra of 71Ga in chalcogenide glasses.
Research
RF Safe Research Library
Jan 1, 2010
This paper discusses the Czjzek model for distributions of electric field gradient (EFG) tensors in disordered solids and highlights its underlying assumptions and characteristics. It then introduces an extended model that combines a defined local EFG environment with an adjustable Gaussian (Czjzek) noise term to…
Slow relaxation of magnetoresistance in AlGaAs-GaAs quantum well structures quenched in a magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This study reports slow relaxation of magnetoresistance in selectively doped p-GaAs-AlGaAs structures following application of a magnetic field. The authors emphasize efforts to rule out temperature fluctuation artifacts and state that the main relaxation features remain. They interpret the phenomenon using a…
The influence of temperature and electric field history on the conductivity of the charge density wave system o-TaS3.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory study examined how temperature and prior electric-field exposure affect low-field conductivity in the charge density wave material o-TaS3. Conductivity differed between cooling and heating below the CDW transition, and applying increasing electric fields drove the system toward a stable,…
Electromagnetic fields and DNA damage
Research
RF Safe Research Library
Jan 1, 2009
This review discusses the comet assay and summarizes research on non-ionizing EMF exposure and DNA/chromosomal damage. It describes both positive and negative findings across studies, noting no consistent overall pattern for radiofrequency radiation (RFR). The authors nonetheless conclude that under certain exposure…
Cell phones and brain tumors: a review including the long-term epidemiologic data
Research
RF Safe Research Library
Jan 1, 2009
This paper presents a meta-analysis of 11 peer-reviewed epidemiologic studies examining long-term (>=10 years) cell phone use with laterality analyses. It reports that long-term use is associated with an approximately doubled risk of an ipsilateral brain tumor. The abstract states statistical significance for glioma…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
The use of pulsed radiofrequency treatment for chronic benign pancreatitis pain.
Research
RF Safe Research Library
Jan 1, 2009
This paper reports on pulsed radiofrequency treatment as an interventional approach for pain due to chronic benign pancreatitis. The authors describe their experience in two patients and characterize the technique as minimally neurodestructive and potentially able to reduce pain perception by altering nerve…
The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.
Research
RF Safe Research Library
Jan 1, 2009
This paper describes a procedural technique for transseptal puncture that uses brief pulses of radiofrequency energy delivered from a standard electrosurgical cautery generator through the needle tip. The approach is presented as a way to facilitate septal traversal when tissue is elastic, aneurysmal, or thickened,…
A new approach for explanation of specimen rupture under high electric field.
Research
RF Safe Research Library
Jan 1, 2009
This engineering-focused study examines failure of needle-shaped specimens exposed to very high electric fields in field-ion microscopy. The authors report experiments indicating breakdown may be initiated by nanoparticles detached from a point anode. They propose a mechanism in which expanding cathode plasma…
The Distracting Effects of a Ringing Cell Phone: An Investigation of the Laboratory and the Classroom Setting.
Research
RF Safe Research Library
Jan 1, 2009
This paper reports four experiments examining how a ringing cell phone affects cognitive performance in laboratory tasks and a college classroom lecture. In the lab, auditory conditions (including a standard cell phone ring) produced slower responses than silence, with slower recovery in the ring and song conditions.…
Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study measures and simulates screening current induced magnetic fields (SCF) in a Bi2223-tape HTS insert used in an LTS/HTS NMR magnet at 77 K. SCF was induced by the insert self-field, an external 5-T background magnet, and their combination, and axial field distributions and temporal variations…
Plasmonic array nanoantennas on layered substrates: modeling and radiation characteristics.
Research
RF Safe Research Library
Jan 1, 2009
This theoretical/engineering study models arrays of plasmonic core-shell nano-radiators positioned over layered substrates using a Green's function dipole approach. The model is validated with full-wave FDTD simulations. The authors report that nanoparticle arraying and multilayer substrate design can be used to…
Biological proton pumping in an oscillating electric field.
Research
RF Safe Research Library
Jan 1, 2009
This paper models biological proton pumping in cytochrome c oxidase under an applied oscillating electric field. The authors report that proton pumping efficiency and steady-state electronic currents vary significantly with the field’s frequency and amplitude. A spectral analysis is described as supporting dominant…
Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.
Research
RF Safe Research Library
Jan 1, 2009
This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…
Microscopic dynamics of the orientation of a hydrated nanoparticle in an electric field.
Research
RF Safe Research Library
Jan 1, 2009
This paper uses atomistic simulations to examine how a nonpolar nanoparticle suspended in water reorients under an applied electric field. The authors report that molecular-level effects increase the torque relative to continuum estimates and substantially speed up reorientation above a stated field threshold. The…
Focused-ion-beam-assisted magnet fabrication and manipulation for magnetic field detection applications.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study describes a focused-ion-beam-assisted technique for fabricating reduced-size NdFeB nanomagnets and integrating them onto a thin-film bulk acoustic resonator (FBAR). After bonding the magnet, the FBAR showed a downshift in resonance frequency and a reduced quality factor. The magnetic behavior…
Role of cortical cell type and morphology in subthreshold and suprathreshold uniform electric field stimulation in vitro.
Research
RF Safe Research Library
Jan 1, 2009
This in vitro study examined how cortical neuron morphology and cell type relate to responses under subthreshold and suprathreshold uniform electric fields in rat motor cortex slices. The authors report that morphology correlates with subthreshold somatic polarization and that layer V pyramidal neurons are predicted…
Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study examined how a DC bias electric field affects the resonance frequency shift of a PMN-PT/tin piezoelectric microcantilever sensor during humidity detection. The authors report that applying a bias field enhanced the relative resonance frequency shift, with a maximum enhancement of more than…