Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality.
Research
RF Safe Research Library
Jan 1, 2012
This engineering study evaluated long-term encapsulation and packaging reliability of a fully wireless 100-channel Utah Slant Electrode Array system in vitro. The device was soaked in PBS for over 12 months while being wirelessly powered/configured at 2.765 MHz and transmitting an FSK-modulated 900 MHz RF signal. The…
A robotic assistant for trans-oral surgery: the robotic endo-laryngeal flexible (Robo-ELF) scope.
Research
RF Safe Research Library
Jan 1, 2012
This paper describes an engineering/clinical tool development effort: the Robotic EndoLaryngeal Flexible (Robo-ELF) Scope System for manipulating flexible endoscopes in laryngeal surgery. The system includes multiple degrees of freedom, a passive positioning arm, and a custom joystick controller enabling one-handed…
Effects of radiofrequency radiation exposure on blood-brain barrier permeability in male and female rats
Research
RF Safe Research Library
Jan 1, 2011
This rat study tested whether acute exposure to 0.9 and 1.8 GHz continuous-wave radiofrequency radiation alters blood-brain barrier permeability. Using Evans-blue/albumin as a tracer, the authors report no BBB leakage in exposed female rats but a significant increase in albumin in exposed male rat brains versus sham.…
Effects of chain stiffness and salt concentration on responses of polyelectrolyte brushes under external electric field.
Research
RF Safe Research Library
Jan 1, 2011
This paper reports molecular dynamics simulations of polyelectrolyte brushes subjected to external electric fields, focusing on how chain stiffness and salt concentration affect responses. The simulations suggest higher salt concentrations strengthen an induced opposing field from ion redistribution, which resists…
Hematological and toxicogenomic effects of ferromagnetic screening of natural electromagnetic fields.
Research
RF Safe Research Library
Jan 1, 2011
This rat study tracked hematological and toxicogenomic aftereffects over 45 days following 2 days of ferromagnetic screening of natural electromagnetic fields. The authors report leukopenia at day 14 and increases in genomic instability markers (aneuploidy and polyploidy) in male leukocytes persisting after screening…
[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].
Research
RF Safe Research Library
Jan 1, 2011
This paper describes the design and preliminary implementation of a mobile-phone-based wireless blood pressure monitoring system that transmits data via Bluetooth and computes blood pressure and heart rate on the phone. The authors state that experiments demonstrated the device’s reliability and stability, and that…
[Psychophysiological indicators for children using mobile phones. Communication 1. Current state of the problem].
Research
RF Safe Research Library
Jan 1, 2011
This article reviews epidemiological and experimental evidence on electromagnetic radiation from mobile phones in humans and animals. It focuses in detail on potential effects on children. The abstract reports that children are more sensitive to this type of exposure than adults.
A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.
Research
RF Safe Research Library
Jan 1, 2011
This paper reports the development of a 15-channel transmit-receive RF coil for 7 T human brain MRI, using a hybrid decoupling approach to support element placement along three axes. The design is presented as enabling B1+ shimming and parallel imaging acceleration in three dimensions, with reported isolation and…
Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.
Research
RF Safe Research Library
Jan 1, 2011
This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…
Reduction of implant RF heating through modification of transmit coil electric field.
Research
RF Safe Research Library
Jan 1, 2011
This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…
Transient and steady-state magnetic fields induce increased fluorodeoxyglucose uptake in the rat hindbrain.
Research
RF Safe Research Library
Jan 1, 2011
This animal PET study examined whether a weak 60-Hz magnetic field alters brain glucose utilization in rats. The abstract reports increased FDG uptake in hindbrain voxels when a 2.5-G field was oriented orthogonally to the sagittal plane, but not when field direction varied randomly. Distinct activation effects were…
Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.
Research
RF Safe Research Library
Jan 1, 2011
This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…
Evaluation of magnetic resonance safety of veterinary radiofrequency identification devices at 1 T.
Research
RF Safe Research Library
Jan 1, 2011
This study evaluated MRI safety parameters for three commercial veterinary RFID microchips at 1 T, assessing movement forces, heating, artifacts, and device function. Translation and torque were reported to be larger than expected from normal activity, but no significant heating was observed and microchip function…
Frequency-dependent electrodeformation of giant phospholipid vesicles in AC electric field.
Research
RF Safe Research Library
Jan 1, 2010
This paper presents a theoretical model of giant phospholipid vesicle deformation in an alternating-current electric field, based on minimizing membrane bending energy and electric-field energy. The model treats the membrane and surrounding aqueous media as leaky dielectrics and reports good quantitative agreement…
Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.
Research
RF Safe Research Library
Jan 1, 2010
This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…
[Dependence of the non-thermal radiofrequency electromagnetic field bioeffects on the typological features of electroencephalogram in humans].
Research
RF Safe Research Library
Jan 1, 2010
This volunteer study examined short-term non-thermal RF EMF exposure and reported changes in EEG spectra. The main reported effect was amplification of alpha-range energy, with the magnitude depending on baseline EEG typological features. The abstract also reports that combining RF EMF exposure with monotonous…
Spin current pumped by a rotating magnetic field in zigzag graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study models electron spin resonance and spin/charge pumping in zigzag graphene nanoribbons driven by a transverse rotating magnetic field without applied bias. It reports that pumped spin current density increases with ribbon size and rotating-field intensity, and that even-chain ribbons can also…
High magnetic field induced charge density waves and sign reversal of the Hall coefficient in graphite.
Research
RF Safe Research Library
Jan 1, 2010
This condensed-matter study investigates highly oriented pyrolytic graphite under very strong magnetic fields at low temperature. It reports a magnetic-field-induced charge density wave transition and a subsequent sign reversal of the Hall coefficient from negative to positive. The reported angular dependence…
Interaction quench dynamics in the Kondo model in the presence of a local magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study analyzes quench dynamics in the Kondo model on the Toulouse line in the presence of a local magnetic field. The authors report exact analytical results for local spin dynamics, finding that relaxation timescales are set by the Kondo scale. They also describe damped transient oscillations in…
Effects of magnetic field and pressure on the intermediate valence state of YbPd.
Research
RF Safe Research Library
Jan 1, 2010
This condensed-matter physics study examined how high magnetic fields and pressure affect magnetization, transport, and thermodynamic properties of the intermediate-valence compound YbPd. The authors report that the Yb valence state and two first-order transitions are stable up to 55 T, while increasing pressure…
The effect of magnetic field and disorders on the electronic transport in graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This paper presents a mesoscopic transport modeling framework (NEGF plus a real-space π-orbital model) to study how a uniform perpendicular magnetic field affects electronic transport in armchair graphene nanoribbons. The authors report width-dependent equilibrium current profiles and edge-localized transport under…
Electron dynamics in inhomogeneous magnetic fields.
Research
RF Safe Research Library
Jan 1, 2010
This paper is a review of two-dimensional electron dynamics in microscopically inhomogeneous magnetic fields, focusing on magnetic potentials varying on scales smaller than the mean free path. It covers early work on localization in random magnetic fields, methods to fabricate magnetic potentials, and drift-diffusion…
Pressure and magnetic field dependence of valence and magnetic transitions in EuPtP.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory study investigates how magnetic field and pressure affect valence and magnetic transitions in the compound EuPtP. High-field analysis suggests a mixed valence state at low temperature and discontinuous changes in Eu2+ fraction at two transition temperatures. Pressure increases the transition…
Thermodynamic behavior of the XXZ Heisenberg s = 1/2 chain around the factorizing magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This paper theoretically investigates zero- and finite-temperature behavior of an anisotropic antiferromagnetic Heisenberg XXZ spin-1/2 chain under a transverse magnetic field, focusing between the factorizing and critical fields. It reports an entanglement phase transition at the factorizing field where entanglement…
The influence of temperature and electric field history on the conductivity of the charge density wave system o-TaS3.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory study examined how temperature and prior electric-field exposure affect low-field conductivity in the charge density wave material o-TaS3. Conductivity differed between cooling and heating below the CDW transition, and applying increasing electric fields drove the system toward a stable,…