Archive

29 posts

Filters: category: Medical Devices Clear

Impact of magnetic fields from tablets, laptops, smartphones, and household/leisure magnets on cardiac implantable electronic devices

Research RF Safe Research Library Jan 1, 2025

This study tested magnetic fields from tablets, laptops, smartphones, and household/leisure magnets against 13 cardiac implantable electronic device (CIED) models to assess magnet mode activation. It reports that these consumer devices can trigger magnet mode when in close proximity, with median activation distances…

A Novel Design of a Portable Birdcage via Meander Line Antenna (MLA) to Lower Beta Amyloid (Aβ) in Alzheimer's Disease.

Research RF Safe Research Library Jan 1, 2025

This translational engineering paper describes a portable RF birdcage/meander line antenna concept for repeated electromagnetic field stimulation at 64 MHz aimed at lowering amyloid-beta in Alzheimer’s disease. The abstract reports prior in vitro findings in primary human brain cultures showing reduced secreted Aβ-42…

Validation of Electromagnetic Field Sensor Performance Through Porcine Skulls: Implications for Neurostimulation and Recording Techniques.

Research RF Safe Research Library Jan 1, 2025

This animal validation study tested a Mu-metal-shielded helmet system with proprietary induction sensor stimulators for non-invasive recording and stimulation of neural electromagnetic activity through porcine skulls. The authors report that EMFs penetrated the swine skull and that sensor performance remained…

Improved assessment of radiofrequency electromagnetic field power deposition near orthopaedic device using a bone-inclusive ASTM phantom under 1.5T and 3T MRI.

Research RF Safe Research Library Jan 1, 2024

This engineering/simulation study proposes a bone-inclusive ASTM phantom to improve assessment of RF power deposition near orthopaedic implants during 1.5 T and 3 T MRI. Using numerical simulations across multiple implant families, the authors report better correlation of peak 1 g SAR near implants with anatomically…

Heating of metallic orthodontic devices during anti-aging treatment with vacuum and electromagnetic fields: In vitro study.

Research RF Safe Research Library Jan 1, 2024

This in vitro study evaluated heating of metallic orthodontic brackets/wires during an anti-aging treatment combining vacuum and electromagnetic fields (V-EMF). Using 20 resin-mouth setups covered with porcine muscle tissue, both beta-titanium and nickel-titanium wire groups showed about a 1.1°C temperature rise by…

Non-Ionizing Radiation in Swedish Health Care-Exposure and Safety Aspects.

Research RF Safe Research Library Jan 1, 2019

This review describes non-ionizing radiation (EMF and optical radiation) methods used in Swedish health care and considers anticipated exposure levels and potential hazards. The authors report that acute effects cannot be ruled out for MRI, transcranial magnetic stimulation, and electrosurgery, and that optical…

Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields - Practical approach to the requirements of European Directive 2013/35/EU.

Research RF Safe Research Library Jan 1, 2018

This study assessed electromagnetic field exposure near common strong EMF sources in medical and industrial workplaces to estimate standard safety distances (SSD) for workers using active implantable medical devices (AIMD). Using measurements near 127 devices, the longest SSDs were reported near dielectric sealers…

Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry.

Research RF Safe Research Library Jan 1, 2017

This engineering study describes miniaturized, flexible, battery-free wearable pulse oximetry systems that use near-field communication (NFC) for wireless operation. The devices capture and transmit photoplethysmograms to derive blood oxygenation, heart rate, and heart rate variability. The abstract reports…

A wearable bluetooth LE sensor for patient monitoring during MRI scans.

Research RF Safe Research Library Jan 1, 2016

This engineering paper reports a prototype wearable patient-monitoring device that transmits vital-sign measurements via Bluetooth LE during MRI. Across 7 MRI acquisitions (25 minutes total), the authors report no Bluetooth packet loss, increased PPG noise during MRI, and no effect on temperature/humidity readings.…

In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.

Research RF Safe Research Library Jan 1, 2016

This engineering study uses a 3D electromagnetic solver to simulate in-to-out body RF path loss for a wireless capsule endoscopy link. The capsule antenna is tuned for the 402 MHz MICS band while accounting for human body properties. The authors examine how capsule misalignment, rotation, and the human body model…

Improving resolution of robotic capsule locomotion using dynamic electromagnetic field.

Research RF Safe Research Library Jan 1, 2016

This engineering conference paper describes a method for controlling the locomotion of swallowable wireless capsule endoscopy devices using a dynamic magnetic field generated by external coils. A permanent magnet embedded in the capsule is manipulated by adjusting external field strengths to maintain equilibrium for…

Wireless Communication of Intraoral Devices and Its Optimal Frequency Selection.

Research RF Safe Research Library Jan 1, 2014

This engineering study assesses optimal RF frequencies for wireless communication with intraoral electronic devices using an intraoral tongue drive system as an example. It compares 27 MHz, 433.9 MHz, and 2.48 GHz based on path loss, radiation patterns, and bit error rate tests, with adaptive impedance matching…

Extremely Low Frequency Electromagnetic Field from Convective Air Warming System on Temperature Selection and Distance.

Research RF Safe Research Library Jan 1, 2014

This study measured extremely low frequency electromagnetic field (ELF-EMF) emitted by a convective air warming (forced air warmer) device at different temperature settings and distances. Reported ELF-EMF levels increased with closer proximity and higher temperature settings, with mean values around 18 mG at 30 cm.…

Comparison of submucosal resection and radiofrequency turbinate volume reduction for inferior turbinate hypertrophy: evaluation by magnetic resonance imaging.

Research RF Safe Research Library Jan 1, 2014

This prospective randomized study compared submucosal resection (SMR) with radiofrequency turbinate volume reduction (RFTVR) in 60 patients with inferior turbinate hypertrophy. Both procedures significantly reduced turbinate volume and improved nasal obstruction symptoms and nasal inspiratory peak flow by 2 months.…

Interference between active implanted medical devices and electromagnetic field emitting devices is rare but real: results of an incidence study in a population of physicians in France.

Research RF Safe Research Library Jan 1, 2014

This cross-sectional incidence survey used a postal questionnaire to assess physician-observed interference incidents between EMF-emitting devices and active implanted medical devices (AIMDs) in France. Among 1,188 participating physicians, 16% reported AIMD failures, typically of moderate severity but sometimes…

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors.

Research RF Safe Research Library Jan 1, 2014

This study tested whether radiofrequency emissions from a ringing GSM mobile phone affect home blood glucose monitor readings. Among 45 female nondiabetic students, the group measured in the presence vs absence of a ringing phone showed larger changes between two readings than a repeat-measurement control group…

[Magnetic field numerical calculation and analysis for magnetic coupling of centrifugal blood pump for extracorporeal circulation].

Research RF Safe Research Library Jan 1, 2013

This engineering paper models the driving system of a centrifugal blood pump for extracorporeal circulation, focusing on disc magnetic coupling. It uses a three-dimensional static magnetic field edge element method in Ansys to numerically calculate magnetic fields and analyze how coupling parameters relate to…

[Objectivized evaluation of surgeons exposure to radiofrequency electromagnetic fields -- in the context of exposure duration and Polish and new international requirements regarding workers protection].

Research RF Safe Research Library Jan 1, 2013

This occupational exposure assessment monitored surgeons during 11 surgeries using monopolar electro surgery units and measured electric and magnetic field strengths during cutting and coagulating modes. Electric fields near the cable at 10 cm were reported in the hundreds of V/m, while magnetic fields were

Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication.

Research RF Safe Research Library Jan 1, 2013

This paper describes development and testing of a Wi-Fi–enabled tele-localisation prototype for radiotherapy field localisation using a personal digital assistant (PDA). Trial tests on 30 subjects across multiple treatment regions reported localisation times under 1.5 minutes and similar transmission speeds across…

A wireless magnetoresistive sensing system for an intraoral tongue-computer interface.

Research RF Safe Research Library Jan 1, 2012

This engineering paper presents an intraoral version of the Tongue Drive System (iTDS) built into a dental retainer. It uses four 3-axis magnetoresistive sensors to detect tongue motion and transmits digitized data wirelessly via a dual-band 27/432 MHz transmitter, with configuration updates via a 13.56 MHz inductive…

Use of a hip arthroscopy flexible radiofrequency device for capsular release in frozen shoulder.

Research RF Safe Research Library Jan 1, 2012

This article describes a surgical technique for arthroscopic capsular release in adhesive capsulitis using a flexible hip arthroscopy radiofrequency ablator. The authors present it as a creative approach intended to improve safety and precision in a procedure that can be technically challenging. The abstract does not…

A robotic assistant for trans-oral surgery: the robotic endo-laryngeal flexible (Robo-ELF) scope.

Research RF Safe Research Library Jan 1, 2012

This paper describes an engineering/clinical tool development effort: the Robotic EndoLaryngeal Flexible (Robo-ELF) Scope System for manipulating flexible endoscopes in laryngeal surgery. The system includes multiple degrees of freedom, a passive positioning arm, and a custom joystick controller enabling one-handed…

Isolated Atrial Lead Conduction Delay following Right Atrial Radiofrequency Maze Procedure.

Research RF Safe Research Library Jan 1, 2011

This case report describes a 60-year-old man with a dual-chamber implantable cardioverter defibrillator who underwent septal myectomy and a right atrial radiofrequency maze procedure. Following surgery, a persistent delay in atrial sensing was observed. The authors attribute this most likely to iatrogenic right…

In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillators.

Research RF Safe Research Library Jan 1, 2010

This in vitro study tested electromagnetic compatibility between passive RFID readers and 15 pacemakers plus 15 ICDs across 134 kHz, 13.56 MHz, and 915 MHz bands. EMI reactions were common with low-frequency RFID and rare with high-frequency RFID, while no reactions were observed with ultra-high-frequency or…

Mitomycin C-associated radiofrequency microelectrocautery used in myringotomy in an animal model.

Research RF Safe Research Library Jan 1, 2009

This experimental animal study compared tympanic membrane closure time after myringotomy performed by microknife versus radiofrequency microcautery, with and without mitomycin C. Radiofrequency myringotomy differed significantly from knife myringotomy, and the 0.7 mm radiofrequency tip combined with mitomycin C was…

Page 1 / 2 Next →