Numerical Analysis of Human Head Exposure to Electromagnetic Radiation Due to 5G Mobile Phones
Research
RF Safe Research Library
Jan 1, 2025
This conference paper uses numerical simulations to evaluate near-field exposure and thermal effects in a detailed human head model from a realistic 5G mobile phone operating at 26 GHz. The preliminary modeling suggests moderate, localized temperature increases in superficial tissues. The authors emphasize the need…
Performance Evaluation and Calibration of Electromagnetic Field (EMF) Area Monitors Using a Multi-Wire Transverse Electromagnetic (MWTEM) Transmission Line.
Research
RF Safe Research Library
Jan 1, 2025
This engineering study evaluates and calibrates an EMF area monitor for the 300 kHz–20 MHz frequency band using a multi-wire transverse electromagnetic (MWTEM) transmission line as a controlled electric-field source. The authors highlight that low-frequency electric-field measurements can be sensitive to boundary…
C-phycocyanin extraction assisted by pulsed electric field from Artrosphira platensis.
Research
RF Safe Research Library
Jan 1, 2017
This engineering/food-processing study evaluates pulsed electric field (PEF) treatment of fresh Artrhospira platensis biomass to enhance aqueous extraction of C-phycocyanin. Extraction depended on electric field strength, treatment time, and application temperature, with higher temperatures reducing the required…
The effects of human height and mass on the calculated induced electric fields at 50 Hz for comparison with the EMF Directive 2013/35/EU.
Research
RF Safe Research Library
Jan 1, 2017
This computational study examined how human height and mass influence calculated induced electric fields in the body from external 50 Hz electric and magnetic fields. Anatomically realistic human models derived from the MAXWEL phantom were varied across a range of heights and masses and used to simulate induced…
Magnetophoretic Conductors and Diodes in a 3D Magnetic Field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study demonstrates magnetophoretic track designs that transport single magnetized beads and magnetically labeled single cells in a 3D time-varying magnetic field. A vertical field bias is reported to reduce particle clustering but necessitates redesigned track geometries with alternating curvature.…
Thick multilayered (silica/gold) dipole nano-antenna.
Research
RF Safe Research Library
Jan 1, 2015
This engineering study examines composite optical dipole nano-antennas made of alternating silica and gold layers. It reports that a 50% filling factor yields a 2.0× increase in electric-field enhancement compared with a pure-gold antenna. The abstract frames the work in terms of photonics applications rather than…
Suppression of unimolecular decay of laser desorbed peptide and protein ions by entrainment in rarefied supersonic gas jets under weak electric fields.
Research
RF Safe Research Library
Jan 1, 2014
This engineering-focused paper reports the design principle and performance of a MALDI ion source ("MALDI-2") combining rarefied supersonic gas jets with weak electric fields and injection into gas-filled RF multipoles. The abstract reports rapid collisional cooling (
Ultrafast volumetric B1 (+) mapping for improved radiofrequency shimming in 3 tesla body MRI.
Research
RF Safe Research Library
Jan 1, 2014
This engineering/clinical MRI methods study evaluated ultrafast volumetric DREAM B1+ mapping to refine patient-adaptive RF shimming at 3T. In 20 patients and three volunteers, a multi-slice adaptive RF shimming approach reduced flip-angle deviations and improved B1+ homogeneity compared with central-slice-based…
Analysis of circular wave packets generated by pulsed electric fields.
Research
RF Safe Research Library
Jan 1, 2012
This physics study analyzes circular wave packets in high Rydberg states produced by applying a pulsed electric field to extreme Stark states. It reports a position-dependent energy gradient that creates a correlation between principal quantum number and spatial coordinate, which appears insensitive to the initial…
Nanocomposite dielectrics in PbO-BaO-Na2O-Nb2O5-SiO2 system with high breakdown strength for high voltage capacitor applications.
Research
RF Safe Research Library
Jan 1, 2012
This engineering materials study reports fabrication and characterization of nanocomposite dielectrics in a PbO-BaO-Na2O-Nb2O5-SiO2 glass-ceramic system. X-ray diffraction and microstructural observations describe temperature-dependent phase formation with nanometer-sized crystallites dispersed in a glass matrix. The…
[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].
Research
RF Safe Research Library
Jan 1, 2011
This paper describes the design and preliminary implementation of a mobile-phone-based wireless blood pressure monitoring system that transmits data via Bluetooth and computes blood pressure and heart rate on the phone. The authors state that experiments demonstrated the device’s reliability and stability, and that…
Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.
Research
RF Safe Research Library
Jan 1, 2011
This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…
Ohmic heating of peaches in the wide range of frequencies (50 Hz to 1 MHz).
Research
RF Safe Research Library
Jan 1, 2010
This engineering/food science study examined ohmic heating of peaches at 60 V/cm using bipolar pulses across frequencies from 50 Hz to 1 MHz. Heating time to a target temperature and multiple electrical properties were frequency-dependent, particularly for intact tissue. The authors report faster electro-thermal…
Electrooptical effects in colloid systems subjected to short pulses of strong electric field.
Research
RF Safe Research Library
Jan 1, 2010
This study describes an electrooptical technique for polydisperse colloid solutions using short pulses of strong sine-shaped electric field, intended for systems that cannot withstand prolonged field exposure. The authors report that key particle parameters can still be extracted from the resulting experimental data.…
Effects of magnetic field and pressure on the intermediate valence state of YbPd.
Research
RF Safe Research Library
Jan 1, 2010
This condensed-matter physics study examined how high magnetic fields and pressure affect magnetization, transport, and thermodynamic properties of the intermediate-valence compound YbPd. The authors report that the Yb valence state and two first-order transitions are stable up to 55 T, while increasing pressure…
An extension of the Czjzek model for the distributions of electric field gradients in disordered solids and an application to NMR spectra of 71Ga in chalcogenide glasses.
Research
RF Safe Research Library
Jan 1, 2010
This paper discusses the Czjzek model for distributions of electric field gradient (EFG) tensors in disordered solids and highlights its underlying assumptions and characteristics. It then introduces an extended model that combines a defined local EFG environment with an adjustable Gaussian (Czjzek) noise term to…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
Extraordinary magnetic field enhancement with metallic nanowire: role of surface impedance in Babinet's principle for sub-skin-depth regime.
Research
RF Safe Research Library
Jan 1, 2009
This paper proposes metallic nanowires as complementary structures to metallic nanogaps for enhancing magnetic fields. It reports magnetic field enhancement up to a factor of 300 and presents a surface-impedance-based analytic theory that is numerically confirmed. The authors also report that, in the sub-skin-depth…
Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study examined how a DC bias electric field affects the resonance frequency shift of a PMN-PT/tin piezoelectric microcantilever sensor during humidity detection. The authors report that applying a bias field enhanced the relative resonance frequency shift, with a maximum enhancement of more than…
Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…
Plasma-assembled carbon nanotubes: electric field-related effects.
Research
RF Safe Research Library
Jan 1, 2008
This engineering-focused paper compares carbon nanotube growth in dense low-temperature plasma versus on a substrate surface using hybrid/Monte-Carlo simulations. It reports that plasma parameters strongly influence ion fluxes and nanotube growth kinetics, with large differences in growth rates and fluxes between…
In-line application of electric field in capillary separation systems: Joule heating, pH and conductivity.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study investigated factors affecting current when an electric field is applied in-line in a capillary separation system. Temperature measurements and a replicated cooling setup were used to estimate Joule heating effects, which were reported to be relatively small. In contrast, significant pH shifts…
AC electric field-induced alignment and long-range assembly of multi-wall carbon nanotubes inside aqueous media.
Research
RF Safe Research Library
Jan 1, 2007
This engineering study examines multi-wall carbon nanotubes suspended in water exposed to AC electric fields generated by 3D electrodes. It reports field-induced polarization leading to nanotube alignment and long-range, electrically conducting assemblies spanning the electrode gap, with assembly length controlled by…