Integrated influence of sulfide modification on the reactivity of nanoscale zero-valent iron towards decabromodiphenyl ether under an electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2024
This laboratory/engineering study examined how sulfide modification of nanoscale zero-valent iron interacts with an electromagnetic field to degrade decabromodiphenyl ether. The combined sulfidation+EMF condition reportedly increased the specific reaction rate constant by 7–10× versus nZVI alone. The abstract…
Enhanced dechlorination of trichloroethene by sulfidated microscale zero-valent iron under low-frequency AC electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2022
This laboratory remediation study evaluates low-frequency AC electromagnetic field (AC EMF) induction heating of sulfidated microscale zero-valent iron (S-mZVI) to enhance dechlorination of trichloroethene (TCE). The authors report substantially higher heating of S-mZVI under AC EMF and faster TCE degradation than…
Spectral density constraints on wireless communication.
Research
RF Safe Research Library
Jan 1, 2020
This paper discusses how rising man-made EMF from modern wireless technologies motivates careful regulation to keep exposure below levels expected to cause harm. It argues current regulations may not strictly constrain EMF when multiple nearby devices transmit simultaneously. The authors propose a…
Improving resolution of robotic capsule locomotion using dynamic electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering conference paper describes a method for controlling the locomotion of swallowable wireless capsule endoscopy devices using a dynamic magnetic field generated by external coils. A permanent magnet embedded in the capsule is manipulated by adjusting external field strengths to maintain equilibrium for…
Magnetophoretic Conductors and Diodes in a 3D Magnetic Field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study demonstrates magnetophoretic track designs that transport single magnetized beads and magnetically labeled single cells in a 3D time-varying magnetic field. A vertical field bias is reported to reduce particle clustering but necessitates redesigned track geometries with alternating curvature.…
Data supporting the role of electric field and electrode material on the improvement of the ageing effects in hydrogenated amorphous silicon solar cells.
Research
RF Safe Research Library
Jan 1, 2015
This Data in Brief article provides additional experimental data supporting a related study on mitigating ageing effects (Staebler-Wronski effect) in hydrogenated amorphous silicon solar cells. The associated method involves applying reverse bias stress and evaluating how temperature, electric field intensity,…
Extraction of Cations from an Ionic Liquid Droplet in a Dielectric Liquid under Electric Field.
Research
RF Safe Research Library
Jan 1, 2014
This laboratory study investigates various ionic liquids using an electrophoresis of a charged droplet method in a dielectric liquid under an applied electric field. While charged droplets typically bounce between electrodes, the authors report that some ionic liquids exhibit a retreating behavior. They interpret…
Electric Fields Control TiO2(e(-)) + I3(-) → Charge Recombination in Dye-Sensitized Solar Cells.
Research
RF Safe Research Library
Jan 1, 2014
This engineering/physical chemistry study quantified interfacial electric fields in dye-sensitized solar cells using a newly described electroabsorption signature. Reported field strengths depended on the electrolyte cation (higher for divalent cations) and were linked to TiO2(e−) + I3− charge recombination kinetics…
Sensitivity enhancement of Faraday effect based heterodyning fiber laser magnetic field sensor by lowering linear birefringence.
Research
RF Safe Research Library
Jan 1, 2013
This engineering study describes a method to improve the sensitivity of Faraday-effect-based heterodyning fiber laser sensors for magnetic field measurement. It reports an inverse relationship between magnetic-field sensitivity and intra-cavity linear birefringence, supported by theory and experimental birefringence…
The effect of magnetic field and disorders on the electronic transport in graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This paper presents a mesoscopic transport modeling framework (NEGF plus a real-space π-orbital model) to study how a uniform perpendicular magnetic field affects electronic transport in armchair graphene nanoribbons. The authors report width-dependent equilibrium current profiles and edge-localized transport under…
Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study measures and simulates screening current induced magnetic fields (SCF) in a Bi2223-tape HTS insert used in an LTS/HTS NMR magnet at 77 K. SCF was induced by the insert self-field, an external 5-T background magnet, and their combination, and axial field distributions and temporal variations…
AC electric field-induced alignment and long-range assembly of multi-wall carbon nanotubes inside aqueous media.
Research
RF Safe Research Library
Jan 1, 2007
This engineering study examines multi-wall carbon nanotubes suspended in water exposed to AC electric fields generated by 3D electrodes. It reports field-induced polarization leading to nanotube alignment and long-range, electrically conducting assemblies spanning the electrode gap, with assembly length controlled by…